Skip to content

What are you looking for?


You may also like

GE IC695SPF550 RX3i SFP Fiber Module 1000Base-SXGE IC695SPF550 RX3i SFP Fiber Module 1000Base-SXGE IC695SPF550 RX3i SFP Fiber Module 1000Base-SX
GE IC695SPF550 RX3i SFP Fiber Module 1000Base-SX
GE IC695SPF550 RX3i SFP Fiber Module 1000Base-SX
GE IC695SPF550 RX3i SFP Fiber Module 1000Base-SX

GE IC695SPF550 RX3i SFP Fiber Module 1000Base-SX


Only 10 left - Selling fast

PRODUCT SKU : IC695SPF550

PRODUCT TYPE : Fiber Optic Transceiver Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The IC695SPF550 is a high-performance Small Form-Factor Pluggable (SFP) fiber transceiver designed for the GE Fanuc RX3i PACSystems series. It delivers reliable high-speed communication over multimode fiber networks, ensuring seamless PROFINET integration and robust industrial connectivity in complex control systems.

Key Features:

  • Brand: GE Fanuc

  • Model: IC695SPF550

  • Series: RX3i PACSystems

  • Module Type: SFP Fiber Optic Transceiver

  • Communication Protocol: PROFINET

  • Connector Type: LC duplex

  • Fiber Type: Multimode 50/125 µm or 62.5/125 µm

  • Transmission Speed: 100 Mbps

  • Maximum Distance: Up to 2 km

  • Number of Ports: 8

  • Form Factor: SFP for compact installation

  • Power Requirements: 1.9 A at 3.3 V / 1.1 A at 5 V

  • Operating Temperature: 0°C to 60°C

  • Storage Temperature: -40°C to 85°C

  • Terminal Type: RJ45 / SFP cage

  • Weight: 3.00 lbs

Applications:

  • High-speed industrial process networks

  • PROFINET-based factory automation systems

  • Redundant or high-availability fiber optic networks

  • Machine-to-machine communication in production lines

  • Data-intensive monitoring and control applications

FAQ:

  • Q1: Is this module compatible with single-mode fiber?
    A: No, it is specifically designed for multimode fiber. Single-mode fiber requires a different SFP module.

  • Q2: Can multiple modules be installed in a single RX3i chassis?
    A: Yes, the compact SFP form factor allows multiple installations in dense configurations.

  • Q3: What is the maximum operating distance?
    A: Up to 2 km depending on the fiber type and network setup.

  • Q4: Does it require special PROFINET configuration?
    A: No, it integrates directly with RX3i Ethernet modules following standard PROFINET settings.

  • Q5: What is the operating temperature range?
    A: 0°C to 60°C for operation, and -40°C to 85°C for storage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more