PRODUCT SKU : DS200SLCCG3ADC

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for network interfacing within Mark V drive and turbine control platforms, the GE DS200SLCCG3ADC (DS200SLCCG3 LAN Communication Card) provides direct physical data exchange and local control processing.

Hardware Specifications

Parameter Specification
Model DS200SLCCG3ADC
Brand General Electric
Origin Not specified
Core Components Integrated LAN control processor (LCP), 2 EPROM memory cartridges

Industrial Control & Firmware Compatibility

The DS200SLCCG3ADC utilizes an integrated LAN Control Processor (LCP) to manage data exchange via dual-ported RAM. For deterministic system performance, backplane bus communication velocity must be verified against the host drive control board requirements. Firmware flash compatibility is governed by the two onboard replaceable EPROM cartridges; these must maintain revision parity with the drive control board software to ensure stable network signal filtering. The module supports both isolated and non-isolated signal paths, requiring adherence to grounding standards to maintain I/O density scaling without introducing electrical noise into the communication bus.

Frequently Asked Questions

Q: How is the communication interface established between the card and the host controller?

A: The card utilizes dual-ported RAM to buffer data between the LCP and the drive control processor. This configuration allows simultaneous memory access, facilitating high-speed communication without external polling cycles.

Q: Is the onboard keypad required for module operation?

A: The detachable alphanumeric keypad is a tool for local diagnostic access and configuration. It is not required for the card to execute its primary communication functions, but it provides the interface for viewing system control settings and diagnostics.

Field Installation Guidelines

  • Physical Seating: Ensure the module is securely inserted into the designated drive cabinet slot. Check for complete engagement of all pins to prevent communication errors or intermittent signal drops.
  • Shielding and Grounding: The board features both isolated and non-isolated circuits. Ensure proper termination of all cable shields at the cabinet entrance to prevent electromagnetic interference (EMI) from degrading the LCP signal filtering.
  • Memory Maintenance: Use ESD-safe procedures when handling EPROM cartridges. Ensure cartridges are firmly seated in their respective sockets (U6/U7) to maintain logic integrity.
  • Diagnostic Check: Post-installation, attach the keypad to verify the card's initialization status. Use the provided test points to validate voltage levels if communication handshaking fails during system startup.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more