Skip to content

What are you looking for?


You may also like

Bently Nevada | Proximity Probe | 330104-00-05-05-01-05 3300 XL 8 mmBently Nevada | Proximity Probe | 330104-00-05-05-01-05 3300 XL 8 mmBently Nevada | Proximity Probe | 330104-00-05-05-01-05 3300 XL 8 mm
Bently Nevada | Proximity Probe | 330104-00-05-05-01-05 3300 XL 8 mm
Bently Nevada | Proximity Probe | 330104-00-05-05-01-05 3300 XL 8 mm
Bently Nevada | Proximity Probe | 330104-00-05-05-01-05 3300 XL 8 mm

Bently Nevada | Proximity Probe | 330104-00-05-05-01-05 3300 XL 8 mm


Only 10 left - Selling fast

PRODUCT SKU : 330104-00-05-05-01-05

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 330104-00-05-05-01-05 is an 8 mm proximity probe from Bently Nevada designed for rotor-dynamic displacement monitoring within 3300 XL eddy-current transducer systems. This configuration features an M10 x 1 non-armored thread, a 0 mm unthreaded length, a 50 mm overall case length, and a 0.5-meter coaxial lead. It delivers stable gap-voltage behavior and linear displacement scaling for rotating machinery protection.

Signal Characteristics and Electrical Design

The probe operates as a passive sensor powered by a companion proximitor module, maintaining a calibrated -10 VDC gap-voltage target. The short 0.5-meter cable minimizes impedance variation to enhance phase stability. A miniature coaxial ClickLoc connector equipped with a fluid-resistant boot ensures reliable electrical seating and environmental protection across the connection interface.

Agency Approvals and Hazardous Compliance

This model includes CSA, ATEX, and IECEx hazardous area approvals as indicated by the final option suffix. These certifications verify that the probe complies with international standards for safe installation in classified industrial environments without altering its baseline electrical performance.

Parameter Specification
Model 330104-00-05-05-01-05
Brand Bently Nevada
Product Type 3300 XL 8 mm proximity probe
Thread Type M10 x 1, non-armored
Unthreaded Length 0 mm (-00)
Overall Case Length 50 mm (-05)
Cable Length 0.5 m (1.6 ft) (-05)
Connector Type Miniature coaxial ClickLoc with fluid-resistant boot (-01)
Agency Approvals CSA, ATEX, IECEx (-05)
Power Consumption Passive probe (powered by proximitor)

Field Installation Guidelines

  1. Maintain clean mounting surfaces to ensure stable eddy-current field alignment.
  2. Route probe wiring away from high-current conductors and avoid sharp bends to preserve coaxial impedance.
  3. Verify full ClickLoc connector engagement and ensure cable shielding is terminated only at the proximitor end before energizing the monitoring channel.

Frequently Asked Questions

Q: Does the 0.5-meter cable length require proximitor recalibration?

A: No, the cable length is factory-matched to standard 3300 XL proximitor modules.

Q: Do the agency approvals affect the electrical output characteristics of the probe?

A: No, the certifications relate strictly to hazardous area compliance and do not change the electrical performance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Industrial automation networks, power distribution systems, and complex control loops rely heavily on proper grounding to maintain operational integrity. Therefore, control engineers and electrical specialists must thoroughly understand the distinctions between earthing, grounding, and bonding. In my 15 years of commissioning distributed control systems (DCS) and factory automation architectures, I have encountered numerous mysterious equipment failures caused by improper grounding practices. Below, I clarify these essential concepts and outline the industry standards governing industrial electrical safety.

Read more
Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Industrial automation networks constantly generate vast streams of diagnostic data before major equipment failures occur. Therefore, integrating control systems with maintenance management platforms is essential for maximizing plant uptime. In my 15 years of commissioning programmable logic controllers (PLCs) and supervisory control and data acquisition (SCADA) networks, I have witnessed how raw alarms sit unnoticed in controller buffers. Bridging the gap between automation software and computerized maintenance management systems (CMMS) transforms early warning signals into actionable work orders. Below, I examine how this integration drives predictive maintenance across modern industrial facilities.

Read more
Understanding Industrial Annunciator Panels: Critical Alarm Management in Process Control

Understanding Industrial Annunciator Panels: Critical Alarm Management in Process Control

An industrial annunciator panel is a dedicated visual and audible alert device. It monitors equipment statuses and alerts operators to abnormal process conditions. Traditionally, these panels feature multiple back-lit windows engraved with specific plant alarms. When a sensor trips, the window flashes and a horn sounds to attract immediate operator attention. Therefore, plant personnel quickly identify critical faults across complex factory automation environments.

Read more