PRODUCT SKU : 330851-02-000-060-10-00-00

PRODUCT TYPE : Proximity Probes

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 330851-02-000-060-10-00-00 is a 3300 XL 25 mm proximity probe manufactured by Bently Nevada for accurate vibration and relative position measurements. This specific model features an M30x2 thread case design with a 60 mm overall case length and a 1.0 meter total system length, providing reliable signal transmission for machinery monitoring configurations.

Configuration and Mechanical Build

The probe is designated with a probe case type option of M30x2 thread for secure mounting into machinery housings. It features an unthreaded length option of 0 mm (0 in) alongside an overall case length option of 60 mm. The total cable length option is configured to 1.0 meter (3.3 feet), accommodating close-coupled installations or panel termination layouts.

Protection and Agency Options

This build is supplied with a 00 armor option, meaning it does not include external mechanical armor over the cable. Additionally, the unit carries a 00 agency approval option, indicating that this specific configuration is delivered without regional hazardous area or country-specific agency certifications.

Parameter Specification
Model 330851-02-000-060-10-00-00
Brand Bently Nevada
Product Series 3300 XL 25 mm Proximity Probe
Probe Case Type M30x2 Thread
Unthreaded Length 0 mm (0 in)
Overall Case Length 60 mm
Total Length 1.0 meter (3.3 feet)
Armor No Armor
Agency Approval No Approvals
Weight 0.23 Kg
Shipping Weight 1.5 Kg
Country of Origin U.S.A.

Frequently Asked Questions

Q: What are the case thread specifications for this model?

A: It features an M30x2 thread pattern with a 60 mm overall case length and 0 mm unthreaded length.

Q: Does this configuration include external cable armor or agency approvals?

A: No, this specific part number is built without mechanical cable armor and carries no agency approvals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Designing Robust SCADA Systems for Electrical Substation Automation

Designing Robust SCADA Systems for Electrical Substation Automation

Electrical substation automation requires rigorous engineering standards to guarantee uninterrupted power distribution and grid stability. Therefore, control engineers must design supervisory control and data acquisition (SCADA) architectures with absolute precision. In my 15 years of commissioning power protection and substation automation systems, I have witnessed how meticulous SCADA design prevents catastrophic grid failures. Below, I outline the critical engineering practices required to build reliable substation SCADA solutions.

Read more
Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Industrial automation networks, power distribution systems, and complex control loops rely heavily on proper grounding to maintain operational integrity. Therefore, control engineers and electrical specialists must thoroughly understand the distinctions between earthing, grounding, and bonding. In my 15 years of commissioning distributed control systems (DCS) and factory automation architectures, I have encountered numerous mysterious equipment failures caused by improper grounding practices. Below, I clarify these essential concepts and outline the industry standards governing industrial electrical safety.

Read more
Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Industrial automation networks constantly generate vast streams of diagnostic data before major equipment failures occur. Therefore, integrating control systems with maintenance management platforms is essential for maximizing plant uptime. In my 15 years of commissioning programmable logic controllers (PLCs) and supervisory control and data acquisition (SCADA) networks, I have witnessed how raw alarms sit unnoticed in controller buffers. Bridging the gap between automation software and computerized maintenance management systems (CMMS) transforms early warning signals into actionable work orders. Below, I examine how this integration drives predictive maintenance across modern industrial facilities.

Read more