Product Details
The 330104-00-02-50-02-00 is an 8 mm proximity probe from Bently Nevada, operating as a dedicated eddy-current sensing element for rotor-to-probe displacement measurement within 3300 XL vibration monitoring systems. This configuration features a 0 mm unthreaded length, a 20 mm overall case length, and a 5.0-meter signal path. It provides stable mechanical-to-electrical transduction for industrial rotating machinery protection.
Construction and Core Performance
The probe is constructed with a polyphenylene sulfide tip, a stainless-steel housing, and a Viton O-ring seal to withstand harsh operating conditions. The PPS tip and stainless-steel case maintain stable eddy-current field geometry, reducing thermal drift while supporting the standard -10 VDC gap voltage target across proximitor interfaces.
Configuration and Installation Guidelines
The part number structure designates a 20 mm case length combined with an extended 5.0-meter standard cable terminated with a miniature coaxial ClickLoc connector. The final -00 suffix indicates that agency approvals are not required for this particular unit configuration.
| Parameter | Specification |
|---|---|
| Model | 330104-00-02-50-02-00 |
| Brand | Bently Nevada |
| Product Type | 3300 XL 8 mm proximity probe |
| Unthreaded Length | 0 mm (-00) |
| Overall Case Length | 20 mm (-02) |
| Cable Length | 5.0 m (16.4 ft) (-50) |
| Connector and Cable Type | Miniature coaxial ClickLoc connector, standard cable (-02) |
| Agency Approvals | Not required (-00) |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Housing Material | Stainless steel (SST) with Viton O-ring sealing |
| Power Consumption | Passive eddy-current probe |
Field Installation Guidelines
- Maintain straight, strain-relieved routing of the 5.0-meter cable and avoid tight bends near the ClickLoc connector to preserve coaxial impedance.
- Ensure the probe tip is aligned perpendicular to the rotor surface and verify the gap voltage during commissioning to confirm correct mechanical positioning.
- Bond cable shielding at the driver end only to prevent ground-loop interference.
Frequently Asked Questions
Q: Does the probe require a specific extension cable length for correct scaling?
A: Yes, eddy-current probes must be paired with the exact cable length defined by the part number to maintain -10 VDC gap voltage calibration.
Q: Is the Viton O-ring pressure-tested before shipment?
A: No, standard probes are not pressure-tested; applications requiring verified sealing should utilize custom-tested units.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.