Skip to content

What are you looking for?


You may also like

Allen-Bradley | 2711P-T6C21D8S | PanelView Plus 7 Standard | 6-Inch Operator TerminalAllen-Bradley | 2711P-T6C21D8S | PanelView Plus 7 Standard | 6-Inch Operator TerminalAllen-Bradley | 2711P-T6C21D8S | PanelView Plus 7 Standard | 6-Inch Operator Terminal
Allen-Bradley | 2711P-T6C21D8S | PanelView Plus 7 Standard | 6-Inch Operator Terminal
Allen-Bradley | 2711P-T6C21D8S | PanelView Plus 7 Standard | 6-Inch Operator Terminal
Allen-Bradley | 2711P-T6C21D8S | PanelView Plus 7 Standard | 6-Inch Operator Terminal

Allen-Bradley | 2711P-T6C21D8S | PanelView Plus 7 Standard | 6-Inch Operator Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T6C21D8S

PRODUCT TYPE : HMI Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 2711P-T6C21D8S PanelView Plus 7 Standard terminal is a compact 6-inch operator interface designed for industrial automation systems. It combines a resistive touchscreen, VGA resolution, and multiple communication ports to deliver reliable visualization and control in demanding environments.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PanelView Plus 7 Standard

  • Part Number: 2711P-T6C21D8S

  • Weight: 2.00 lbs (0.91 kg)

  • Display Size: 115 × 86 mm (5.7 inches, widescreen)

  • Display Type: TFT color display

  • Resolution: 640 × 480 VGA, 18-bit graphics

  • Touchscreen: Analog resistive, rated for 1 million actuations, 100 g operating force

  • Backlight: CCFL, minimum 50,000 hours life

  • System Memory: 512 MB RAM and 512 MB storage

  • User Memory: Approx. 80 MB available

  • Communication Ports: 2 × USB, 1 × RS232, 1 × Ethernet

  • Input Voltage Range: 18–30 VDC (nominal 24 VDC)

  • Input Type: Touchscreen interface

  • Display Color: Full color graphics

Application Scenarios

  • Operator Interface: Provides visualization and control for machine-level applications

  • Compact Installations: Ideal for systems requiring smaller display footprints

  • Industrial Automation: Suitable for manufacturing, packaging, and process control environments

FAQ

  • Q: What is the lifespan of the backlight?  A: The CCFL backlight is rated for a minimum of 50,000 hours.

  • Q: How much user memory is available?  A: Approximately 80 MB of user memory is accessible for applications.

  • Q: Which communication ports are included?  A: The 2711P-T6C21D8S includes 2 USB ports, 1 RS232 port, and 1 Ethernet port.

  • Q: How does this model compare to the 2711P-T10C models?  A: The 6-inch 2711P-T6C21D8S is more compact, while the 10-inch models provide larger visualization areas and higher resolution for complex applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

In industrial automation, Programmable Logic Controllers (PLCs) are vital for control and monitoring. Over time, support and spare parts become limited, forcing engineers to decide between upgrading the existing PLC or migrating to a new system to maintain reliability and reduce downtime.

Read more
Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Commissioning a PLC control system is one of the most critical phases in any industrial automation project. It transforms design and programming into a fully functional, reliable system on site. For new PLC programmers, understanding each commissioning step ensures smooth integration, reduced downtime, and successful handover to the client.

Read more
Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

In modern industrial automation, reliable communication between remote I/O and PLCs is essential. The Schneider Electric CRA module enables efficient Ethernet-based remote I/O connectivity in PLC and DCS systems, improving scalability, diagnostics, and overall networked automation performance.



Read more