PRODUCT SKU : 1756-L7SP

PRODUCT TYPE : Safety Partner Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1756-L7SP GuardLogix Safety Partner Module is designed to work alongside 1756-L7xS controllers, providing SIL 3 and PLe certified safety functionality. It ensures compliance with stringent safety standards while maintaining seamless integration into ControlLogix chassis systems.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: GuardLogix / ControlLogix

  • Part Number: 1756-L7SP

  • Product Type: Safety Partner Module for 1756-L7xS Controllers

  • Weight: 0.25 kg

  • Energy Storage Modules:

    • 1756-SPESMNSE (removable, no residual WallClockTime backup)

    • 1756-SPESMNRM (nonremovable, prevents USB and SD card use)

  • Current Draw @ 1.2 VDC: 5 mA

  • Current Draw @ 5.1 VDC: 800 mA

  • Power Dissipation: 2.5 W

  • Thermal Dissipation: 8.5 BTU/hr

  • Isolation Voltage: 30 V continuous, USB port to backplane (basic insulation); type tested at 500 V AC for 60 seconds

  • Slot Width: 2 (requires both modules, each occupies one slot)

  • Module Location: Chassis-based, must be installed immediately to the right of the primary controller

  • Compatible Chassis: 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17

  • Compatible Power Supplies: 1756-PA72, 1756-PB72, 1756-PA75, 1756-PB75

  • Wire Category: Category 3 (USB ports)

Application Scenarios

  • Safety-Critical Automation: Provides SIL 3 and PLe safety compliance for GuardLogix systems

  • Industrial Control Systems: Ensures redundancy and secure operation in manufacturing and process environments

  • Secure Configurations: Nonremovable energy storage module prevents unauthorized USB or SD card access

FAQ

  • Q: What is the role of the 1756-L7SP?  A: It functions as a safety partner for GuardLogix controllers, enabling SIL 3 and PLe safety compliance.

  • Q: Which energy storage modules are supported?  A: The 1756-L7SP supports 1756-SPESMNSE (removable) and 1756-SPESMNRM (nonremovable).

  • Q: Where should the module be installed?  A: It must be placed in the chassis slot immediately to the right of the primary controller.

  • Q: How does this differ from standard ControlLogix modules?  A: Unlike standard modules, the 1756-L7SP is specifically designed for safety applications with SIL 3/PLe certification.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

In industrial automation, Programmable Logic Controllers (PLCs) are vital for control and monitoring. Over time, support and spare parts become limited, forcing engineers to decide between upgrading the existing PLC or migrating to a new system to maintain reliability and reduce downtime.

Read more
Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Commissioning a PLC control system is one of the most critical phases in any industrial automation project. It transforms design and programming into a fully functional, reliable system on site. For new PLC programmers, understanding each commissioning step ensures smooth integration, reduced downtime, and successful handover to the client.

Read more
Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

In modern industrial automation, reliable communication between remote I/O and PLCs is essential. The Schneider Electric CRA module enables efficient Ethernet-based remote I/O connectivity in PLC and DCS systems, improving scalability, diagnostics, and overall networked automation performance.



Read more