Skip to content

What are you looking for?


You may also like

Allen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming CableAllen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming CableAllen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming Cable
Allen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming Cable
Allen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming Cable
Allen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming Cable

Allen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming Cable


Only 10 left - Selling fast

PRODUCT SKU : 1761-CBL-PM02

PRODUCT TYPE : Programming Cable

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1761-CBL-PM02 is a communication and programming cable manufactured by Allen-Bradley, designed for direct connection between a PC serial port and MicroLogix controllers. It provides a stable RS-232 interface, ensuring reliable data transfer during programming, configuration, and diagnostics. This cable is essential for engineers and technicians working with MicroLogix 1000, 1200, and 1500 PLC systems.

Key Features

  • Model Number: 1761-CBL-PM02

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Cable Type: RS-232 communication and programming cable

  • Connector Type: 9-pin D-shell female (PC side) to 8-pin mini-DIN (controller side)

  • Cable Length: 2.5 meters (approx. 8.2 feet)

  • Communication Standard: RS-232 serial interface

  • Compatibility: MicroLogix 1000, 1200, and 1500 controllers; some PanelView terminals

  • Function: Provides point-to-point communication between controller and programming terminal

  • Construction: Shielded cable design for EMI protection and long-term durability

  • Data Transfer Rate: Supports standard baud rates up to 19.2 kbps

  • Plug-and-Play: No external power required; direct connection via serial port

Technical Specifications

  • Operating Temperature: 0°C to 55°C

  • Storage Temperature: -25°C to 70°C

  • Insulation Resistance: High dielectric strength to prevent signal loss

  • Cable Material: Industrial-grade PVC with high flexibility

  • Connector Shell: Nickel-plated for corrosion resistance

Applications

The 1761-CBL-PM02 cable is commonly used for:

  • Programming and configuring MicroLogix PLCs via RS-232

  • Uploading and downloading ladder logic programs

  • Connecting HMIs such as PanelView 300 or 550 to MicroLogix controllers

  • Performing real-time diagnostics and maintenance tasks

FAQ

  • Q1: Which controllers are compatible with the 1761-CBL-PM02?
    A1: It supports MicroLogix 1000, 1200, and 1500 controllers and select PanelView terminals.

  • Q2: What is the cable length?
    A2: The cable is 2.5 meters (approximately 8.2 feet) long.

  • Q3: Can this cable be used with a USB port?
    A3: Not directly. A USB-to-RS-232 adapter is required for use with modern computers.

  • Q4: Is the cable shielded for noise reduction?
    A4: Yes, it includes internal shielding to minimize electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
How to Train Your Maintenance Team for Industrial Automation Systems

How to Train Your Maintenance Team for Industrial Automation Systems

Proper training of maintenance teams is essential to prevent downtime and ensure smooth operations in industrial automation. With PLCs, DCS, SCADA, and IoT systems, technicians need advanced skills to manage complex control systems. This guide provides a structured approach to building a capable team.

Read more
Understanding Fail-Safe in Siemens PLCs for Industrial Automation

Understanding Fail-Safe in Siemens PLCs for Industrial Automation

In industrial automation, safety PLCs provide advanced protection beyond standard types. They safely shut down machinery during faults, reducing external hardware needs. Certified to SIL and IEC/ISO standards, they ensure functional safety in factory automation, protecting both personnel and critical equipment.

Read more
Understanding GE Fanuc Emerson Field Control for Industrial Automation

Understanding GE Fanuc Emerson Field Control for Industrial Automation

GE Fanuc Emerson’s Field Control I/O offered a compact, DIN-rail-mounted solution for industrial automation. Ideal for water treatment and process plants, its integrated design saved panel space and simplified wiring. Though reliable, this line is now obsolete, requiring a shift to modern, high-speed remote I/O.

Read more