Skip to content

What are you looking for?


You may also like

AAI143-H00 | Yokogawa | 16-Channel Isolated Analog Input ModuleAAI143-H00 | Yokogawa | 16-Channel Isolated Analog Input ModuleAAI143-H00 | Yokogawa | 16-Channel Isolated Analog Input Module
AAI143-H00 | Yokogawa | 16-Channel Isolated Analog Input Module
AAI143-H00 | Yokogawa | 16-Channel Isolated Analog Input Module
AAI143-H00 | Yokogawa | 16-Channel Isolated Analog Input Module

AAI143-H00 | Yokogawa | 16-Channel Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAI143-H00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI143-H00 analog input module from Yokogawa is designed for distributed control systems requiring precise current signal acquisition. This model provides 16 isolated input channels for 4–20 mA DC signals, ensuring reliable measurement and integration with smart field devices. The H00 suffix indicates HART communication support combined with a basic hardware configuration.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI143-H00

  • Type: Isolated Analog Input Module

  • Channels: 16 isolated input channels

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: 24 mA

  • Withstanding Voltage: 1500 V AC between input and system (1 minute)

  • Input Resistance:

    • Power ON: 270 Ω at 20 mA, 350 Ω at 4 mA

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Data Update Period: 10 ms

  • Transmitter Power Supply: 19.0 V minimum at 20 mA, 25.5 V maximum at 0 mA (limit 25 mA)

  • Transmitter Configuration: Supports 2-wire and 4-wire transmitters via setting pin

  • Temperature Drift: ±16 µA per 10 °C change

  • Current Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • Weight: 0.3 kg (Shipping weight: 2.0 kg)

  • External Connections: Pressure clamp terminal, MIL connector cable, KS1 cable

  • Communication Protocol: HART-enabled

Suffix Code Breakdown

  • H: HART communication support

  • 0: Basic hardware type

Key Features

  • Isolated Channels: Ensures reliable signal integrity

  • HART Communication: Enables diagnostics and remote configuration

  • High Accuracy: ±16 µA precision for stable measurement

  • Compact Design: Lightweight and efficient for cabinet installation

Application Scenarios

  • Chemical and petrochemical process monitoring

  • Power generation instrumentation

  • Water treatment and distribution systems

  • Industrial automation requiring isolated multi-channel input

FAQ

Q: How many channels does the AAI143-H00 provide?  A: It supports 16 isolated analog input channels.

Q: What does the suffix “H00” indicate?  A: It specifies HART communication support with a basic hardware configuration.

Q: Is redundancy supported?  A: Yes, the module is compatible with dual-redundant configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




  • 5 stars: 4 (80%)
  • 4 stars: 1 (20%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
S
Steven

Tested this module in a power plant environment. Accuracy and stability are impressive, even under temperature variation. Packaging and delivery were professional.

A
Aaron

Overall a solid product. Performance is stable and accurate, but delivery took slightly longer than expected. Still, the supplier kept us updated, which was appreciated.

B
Brandon

Good build quality and consistent readings across all channels. The module integrates smoothly with our existing system. Documentation was clear enough for setup. Would buy again.

K
Kevin

Fast shipping and responsive support from the supplier. We are using all 16 channels in a process plant, and the isolation is excellent—no noise issues so far. Reliable performance.

R
Ryan

The module arrived earlier than expected and was well packaged. Installation into our Yokogawa DCS was straightforward. Signal accuracy is stable, and the HART communication works perfectly for diagnostics. Very satisfied with both product quality and seller service.

Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Programmable Logic Controllers (PLCs) form the backbone of modern industrial automation systems. They interface directly with field devices such as solenoid valves, indicator lights, motor starters, and interposing relays. Selecting the correct digital output module ensures high system availability and long hardware service life.

Read more
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more