Skip to content

What are you looking for?


You may also like

51454416-800 Power Supply Module | Honeywell51454416-800 Power Supply Module | Honeywell51454416-800 Power Supply Module | Honeywell
51454416-800 Power Supply Module | Honeywell
51454416-800 Power Supply Module | Honeywell
51454416-800 Power Supply Module | Honeywell

51454416-800 Power Supply Module | Honeywell


Only 10 left - Selling fast

PRODUCT SKU : 51454416-800

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51454416-800, also cataloged as the 51454416-800 Power Supply Module, operates as a dedicated hardware component for power conversion and regulated DC rail distribution within TDC 3000X, APM, and HPM platforms.

Hardware Specifications

Parameter Specification
Model 51454416-800
Brand Honeywell
Origin USA
Weight 0.4 kg
Dimensions 7 cm x 14 cm x 14.5 cm
Operating Temp -30 to +65 deg C
Power Consumption 200 W Power Output Capacity
Heat Dissipation Up to 180 W
Output Rails +3.3 VDC, +5 VDC, +12 VDC, +24 VDC
Isolation Voltage 2000 V AC
Internal Sensors 6 embedded temperature sensors
System Compatibility TDC 3000X, APM, HPM platforms

Channel-to-Channel Isolation & Cold Junction Compensation

The power module architecture incorporates 2000 V AC dielectric isolation to prevent common-mode voltage noise and ground potential differences from coupling into backplane instrumentation buses. Internal power regulation circuits feed +3.3 VDC, +5 VDC, +12 VDC, and +24 VDC rails, maintaining tight voltage stability across field I/O connections. Six internal thermal sensors continuously monitor temperature profiles across critical power components, maintaining thermal stability for nearby high-density analog modules equipped with cold junction compensation (CJC) for thermocouple processing.

Frequently Asked Questions

Q: How does the module handle thermal protection without an active cooling fan?

A: The module relies on a convection-cooled fanless chassis designed to dissipate up to 180 W of heat, monitored continuously by six internal thermal sensors that trigger system diagnostic alerts if internal limits are exceeded.

Q: What level of galvanic electrical isolation is provided between power inputs and system logic?

A: Internal transformer and optocoupler stages deliver 2000 V AC isolation to protect backplane communication circuits from field-side electrical surges and ground loop currents.

Q: Which DC voltage rails are generated by the 51454416-800 unit for downstream DCS electronics?

A: The module converts primary incoming power into four regulated output rails: +3.3 VDC, +5 VDC, +12 VDC, and +24 VDC.

Field Installation Guidelines

  1. De-energize and lock out primary cabinet power feeds before inserting or removing the power module from the chassis.
  2. Slide the 51454416-800 into the designated power supply slot along the card guide rails until backplane connectors align.
  3. Apply firm pressure to seat the multi-pin edge connectors fully into the rack backplane assembly.
  4. Tighten front panel retaining screws to secure the physical chassis mount and establish low-impedance frame grounding.
  5. Confirm vertical airflow clearance around the fanless housing and verify status LED indicators upon power-up before placing connected system racks into active service.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more