Skip to content

What are you looking for?


You may also like

3500/60-01-R0 Monitor Module | Bently Nevada3500/60-01-R0 Monitor Module | Bently Nevada3500/60-01-R0 Monitor Module | Bently Nevada
3500/60-01-R0 Monitor Module | Bently Nevada
3500/60-01-R0 Monitor Module | Bently Nevada
3500/60-01-R0 Monitor Module | Bently Nevada

3500/60-01-R0 Monitor Module | Bently Nevada


Only 10 left - Selling fast

PRODUCT SKU : 3500/60-01-R0

PRODUCT TYPE : Temperature Monitor Modules

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 3500/60-01-R0 Monitor Module is a six-channel temperature monitoring device designed for the 3500 Machinery Protection System. It accepts inputs from both Resistance Temperature Detectors (RTDs) and Thermocouples (TCs), conditioning the signals to track critical thermal parameters such as bearing and fluid temperatures against user-programmable alarm setpoints.

Channel Inputs and Signal Processing

The module processes up to six temperature transducer channels, supporting multiple sensor configurations including 3-wire and 4-wire platinum, nickel, or copper RTDs, as well as standard thermocouple types. The associated 01 ordering option designates an RTD/TC non-isolated I/O module equipped with internal terminations to handle field wiring directly inside the rack framework.

Parameter Specification
Brand Bently Nevada
Model 3500/60-01-R0
Module Type Temperature Monitor Module
Number of Channels 6 channels
I/O Module Type RTD/TC Non-Isolated with Internal Terminations (-01)
Nominal Power Consumption 7 W
Monitor Module Dimensions 241.3 mm x 24.4 mm x 241.8 mm
I/O Module Dimensions 241.3 mm x 24.4 mm x 99.1 mm
Monitor Module Weight 0.91 kg
I/O Module Weight 0.45 kg
Operating Temperature -30 deg C to +65 deg C
Storage Temperature -40 deg C to +85 deg C

Setpoint Configuration and Alarm Logic

Users configure independent Alert and Danger setpoints for each channel through the 3500 Rack Configuration Software. The module executes programmed alarm time delays and supports proportional recorder outputs to facilitate continuous machine health assessment and automated trip protection.

Frequently Asked Questions

Q: What sensor types are compatible with the 3500/60-01-R0 module?

A: It accepts inputs from resistance temperature detectors (RTDs) and thermocouples (TCs) across its six independent channels.

Q: What does the -01 designation indicate in this part number?

A: The -01 suffix specifies an RTD/TC non-isolated I/O module configuration featuring internal signal terminations.

Q: How are alarm thresholds defined for this temperature monitor?

A: Alert and Danger setpoints are configured by the user via the 3500 configuration software across the operating range of the connected sensors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more