PRODUCT SKU : 330105-02-15-05-02-02

PRODUCT TYPE : Proximity Probes

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 330105-02-15-05-02-02 is a 3300 XL 8 mm proximity transducer system manufactured by Bently Nevada for precise displacement measurement and rotor-dynamic monitoring in rotating machinery. This assembly is engineered to maintain stable gap-voltage behavior and linear scaling when integrated with standard 3300 XL eddy-current probe networks.

Configuration and Mechanical Build

The model configuration incorporates specific structural options designed to match system requirements. It features a total cable length of 0.5 meters (1.6 feet) designated by code 05, paired with a miniature ClickLoc coaxial connector indicated by option 02. This termination design ensures repeatable electrical seating and reliable signal transmission across standard proximitor interfaces.

Signal Characteristics and Compliance

The probe architecture maintains a nominal gap-voltage target to preserve linear displacement scaling across its calibrated operating range. The short 0.5-meter cable minimizes impedance variation to support phase stability. Additionally, the unit carries multiple agency approvals designated by option 02, verifying its compliance with regional safety and hazardous area standards.

Parameter Specification
Model 330105-02-15-05-02-02
Brand Bently Nevada
Product Type 3300 XL 8 mm proximity transducer system
Total Length Option 0.5 m (1.6 ft) (option 05)
Connector Option Miniature ClickLoc coaxial connector (option 02)
Agency Approval Multiple approvals (option 02)
Power Consumption Passive eddy-current probe; powered by proximitor
Shipping Weight 1.5 kg
Country of Origin U.S.A.

Installation Guidelines

  1. Maintain clean mounting surfaces to ensure stable mechanical seating and consistent eddy-current field alignment.
  2. Terminate cable shielding at the proximitor end only to prevent ground-loop formation.
  3. Avoid sharp cable bends to preserve coaxial impedance and minimize signal distortion.
  4. Route probe wiring away from high-current conductors to reduce electromagnetic interference.
  5. Verify ClickLoc connector engagement before energizing the monitoring channel.

Frequently Asked Questions

Q: Can the probe be replaced while the proximitor remains energized?

A: Replacement should occur only with the channel de-energized to avoid transient gap-voltage excursions.

Q: Does the 0.5 m cable length require proximitor recalibration?

A: No, the cable length is factory-matched to standard 3300 XL proximitor modules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Designing Robust SCADA Systems for Electrical Substation Automation

Designing Robust SCADA Systems for Electrical Substation Automation

Electrical substation automation requires rigorous engineering standards to guarantee uninterrupted power distribution and grid stability. Therefore, control engineers must design supervisory control and data acquisition (SCADA) architectures with absolute precision. In my 15 years of commissioning power protection and substation automation systems, I have witnessed how meticulous SCADA design prevents catastrophic grid failures. Below, I outline the critical engineering practices required to build reliable substation SCADA solutions.

Read more
Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Industrial automation networks, power distribution systems, and complex control loops rely heavily on proper grounding to maintain operational integrity. Therefore, control engineers and electrical specialists must thoroughly understand the distinctions between earthing, grounding, and bonding. In my 15 years of commissioning distributed control systems (DCS) and factory automation architectures, I have encountered numerous mysterious equipment failures caused by improper grounding practices. Below, I clarify these essential concepts and outline the industry standards governing industrial electrical safety.

Read more
Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Industrial automation networks constantly generate vast streams of diagnostic data before major equipment failures occur. Therefore, integrating control systems with maintenance management platforms is essential for maximizing plant uptime. In my 15 years of commissioning programmable logic controllers (PLCs) and supervisory control and data acquisition (SCADA) networks, I have witnessed how raw alarms sit unnoticed in controller buffers. Bridging the gap between automation software and computerized maintenance management systems (CMMS) transforms early warning signals into actionable work orders. Below, I examine how this integration drives predictive maintenance across modern industrial facilities.

Read more