2MLR-AC13 Honeywell MasterLogic-200 Power Supply Module2MLR-AC13 Honeywell MasterLogic-200 Power Supply Module2MLR-AC13 Honeywell MasterLogic-200 Power Supply Module
2MLR-AC13 Honeywell MasterLogic-200 Power Supply Module
2MLR-AC13 Honeywell MasterLogic-200 Power Supply Module
2MLR-AC13 Honeywell MasterLogic-200 Power Supply Module

2MLR-AC13 Honeywell MasterLogic-200 Power Supply Module


Only 10 left - Selling fast

PRODUCT SKU : 2MLR-AC13

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 2MLR-AC13, also cataloged as the 2MLR-AC13 Power Supply Module, operates as a dedicated hardware component for redundant power distribution within MasterLogic-200 PLC platforms.

Hardware Specifications

Parameter Specification
Model 2MLR-AC13
Brand Honeywell
Origin Industrial Automation Standard
Weight 1.20 lbs (0.54 kg)
Dimensions Standard MasterLogic-200 Power Rack Mount
Operating Temp 0 to 60 deg C
Power Consumption 100-120 VAC input, 5 VDC nominal backplane output
Output Current 8.5 A at 5 VDC
Module Type Redundant Power Supply Module
Input Voltage Range 100-120 VAC
Series Compatibility MasterLogic L200R Series

Channel Isolation and Power Bus Regulation

The 2MLR-AC13 module incorporates optical channel-to-channel isolation and structured 4-20 mA HART loop compatibility parameters across its system backplane power distribution layer. Internal galvanic isolation prevents line-side surges and ground loops from propagating into sensitive digital logic circuitry across the MasterLogic L200R backplane. The power stage maintains regulated 5 VDC output at currents up to 8.5 A, utilizing dynamic ripple filtering to prevent processor disruption during primary AC supply line voltage fluctuations.

Frequently Asked Questions

Q: Does the 2MLR-AC13 power supply module support redundant configuration in MasterLogic-200 racks?

A: Yes, the module is engineered for dual redundant power configurations, allowing seamless power share and automatic failover without interrupting backplane operations.

Q: What input voltage level is required for operating the 2MLR-AC13?

A: The module accepts an AC line input range of 100-120 VAC to deliver a regulated 5 VDC, 8.5 A bus supply.

Field Installation Guidelines

  1. Ensure main incoming AC power is disconnected and locked out prior to installing the 2MLR-AC13 module into the rack power slot.
  2. Align the module chassis with the dedicated power slot guides on the MasterLogic base unit and press firmly until the locking latches click into place.
  3. Wire the 100-120 VAC input connections using properly rated field wiring, ensuring the safety earth ground conductor is securely bonded to the main terminal screw.
  4. Verify correct backplane power output status via the front panel LED indicators before bringing connected I/O chassis online.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more
Industrial PLC Communication Protocols: A Comprehensive Engineering Guide

Industrial PLC Communication Protocols: A Comprehensive Engineering Guide

Modern factory automation relies heavily on industrial communication protocols to connect field instruments, controllers, and enterprise networks. Beyond traditional hardwired I/O, robust communication networks allow programmable logic controllers (PLCs) to exchange telemetry, diagnostic data, and control commands efficiently across complex architectures.

Read more
Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Programmable Logic Controllers (PLCs) form the backbone of modern industrial automation systems. They interface directly with field devices such as solenoid valves, indicator lights, motor starters, and interposing relays. Selecting the correct digital output module ensures high system availability and long hardware service life.

Read more