PRODUCT SKU : 2MLP-DC42

PRODUCT TYPE : Power Supplies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 2MLP-DC42, also cataloged as the 2MLP-DC42 Power Supply, operates as a dedicated hardware component for internal bus voltage regulation within MasterLogic 200 rack architectures. It converts a nominal 24 VDC input source into a stabilized 5 VDC output at up to 6 A to energize backplane logic circuits and active expansion slots.

Hardware Specifications

Parameter Specification
Model 2MLP-DC42
Brand Honeywell
Origin Industrial Standard Assembly
Weight 1.10 lbs (0.50 kg)
Dimensions Rack Slot Standard
Operating Temp 0 to 55 deg C
Power Consumption Input Current: 0.80 A at 24 VDC
Input Voltage 24 VDC
Output Voltage 5 VDC
Max Output Current 6 A
Input Protection Built-in Internal Fuse
Hold-Up Time 10 ms or shorter
Diagnostic Interface RUN Relay Contact

Channel-to-Channel Isolation & DCS Power Stability

The 2MLP-DC42 incorporates internal galvanic isolation barriers between the 24 VDC input power terminals, the 5 VDC backplane logic rail, and chassis ground. This structural decoupling prevents field-side electrical noise, common-mode voltage spikes, and ground loop current from corrupting 4-20 mA HART loop signals and high-density DCS analog input channels across the rack assembly. Integrated input line filtering stabilizes logic bus rail voltages during brownouts, maintaining execution continuity for up to 10 ms.

Frequently Asked Questions

Q: What protection mechanism is integrated into the 2MLP-DC42 to handle input overcurrent conditions?

A: The module contains an internal built-in fuse on the 24 VDC input line. If an overcurrent fault occurs, the internal fuse opens to prevent electrical damage to the backplane and adjacent processing modules.

Q: How does the RUN contact operate during power state transitions?

A: The RUN relay contact remains closed when the 2MLP-DC42 maintains stable 5 VDC bus output within valid voltage thresholds. If input voltage drops below operating tolerance or an output fault occurs, the contact opens to trigger system diagnostic alarms.

Field Installation Guidelines

  1. Confirm that the primary 24 VDC power supply is switched off before terminating input leads to the 2MLP-DC42 power terminals.
  2. Connect the frame ground (FG) terminal to the central enclosure earth ground bar using a short, low-impedance conductor.
  3. Ensure total current consumption of all CPU, communication, and I/O modules mounted on the backplane does not exceed the 6 A maximum 5 VDC output rating.
  4. Provide a minimum clearance of 50 mm above and below the power supply chassis to allow proper thermal heat dissipation via natural convection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more