Skip to content

What are you looking for?


You may also like

2MLF-AD16A-CC | Honeywell | MasterLogic-200 Analog Input Module2MLF-AD16A-CC | Honeywell | MasterLogic-200 Analog Input Module2MLF-AD16A-CC | Honeywell | MasterLogic-200 Analog Input Module
2MLF-AD16A-CC | Honeywell | MasterLogic-200 Analog Input Module
2MLF-AD16A-CC | Honeywell | MasterLogic-200 Analog Input Module
2MLF-AD16A-CC | Honeywell | MasterLogic-200 Analog Input Module

2MLF-AD16A-CC | Honeywell | MasterLogic-200 Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 2MLF-AD16A-CC

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for multi-channel voltage/current signal acquisition in MasterLogic-200 PLC networks, the Honeywell 2MLF-AD16A-CC (2MLF-AD16A-CC Analog Input Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 2MLF-AD16A-CC
Brand Honeywell
Origin South Korea
Weight 0.115 kg
Dimensions Standard MasterLogic-200 I/O Module Form Factor
Operating Temp 0 to 55 deg C
Power Consumption 330 mA at 5 VDC (internal backplane)
Input Channels 16 channels
Max Conversion Speed 500 us / channel
Accuracy +/-0.2% (at 25 +/-5 deg C), +/-0.3% (at 0 to 55 deg C)
Isolation Method Photo-coupler between input and PLC power (non-isolated channel-to-channel)
Terminal Connection 32-point terminal block
Assigned I/O Addresses Fixed type: 64 points; Variable type: 16 points
Storage Temp -25 to +70 deg C
Operating Humidity 5% to 95% RH (non-condensing)

Process Control Signal Conditioning and Loop Protocol

The 2MLF-AD16A-CC executes high-speed analog-to-digital conversion across 16 field input channels using a photo-coupler isolation barrier rated between the field wiring terminals and the backplane logic power supply. Designed to process 4-20 mA HART loop protocol transmitters and standard analog instrumentation, the module maintains an absolute conversion rate of 500 us per channel while filtering common-mode field noise. Thermal drift compensation algorithms retain signal conversion precision within +/-0.2% under nominal operating conditions.

Frequently Asked Questions

Q: Does the 2MLF-AD16A-CC feature channel-to-channel galvanic isolation?

A: No, the module provides photo-coupler isolation between the field input terminals and the internal PLC backplane power, but does not provide individual isolation between input channels.

Q: How many I/O points are allocated on the backplane bus for the 2MLF-AD16A-CC?

A: The module assigns either 64 fixed points or 16 variable points depending on the configured addressing mode within the MasterLogic-200 system environment.

Field Installation Guidelines

  1. Power off the main backplane chassis prior to seating the 2MLF-AD16A-CC module into the MasterLogic-200 rack slot.
  2. Align the module housing with the base guide rails and press firmly until the upper and lower mounting latches lock securely.
  3. Wire field analog instrumentation to the 32-point terminal block using shielded twisted-pair cabling.
  4. Ground cable shields at a single ground busbar inside the cabinet to prevent stray ground loop currents from affecting measurement accuracy across non-isolated channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more
Industrial PLC Communication Protocols: A Comprehensive Engineering Guide

Industrial PLC Communication Protocols: A Comprehensive Engineering Guide

Modern factory automation relies heavily on industrial communication protocols to connect field instruments, controllers, and enterprise networks. Beyond traditional hardwired I/O, robust communication networks allow programmable logic controllers (PLCs) to exchange telemetry, diagnostic data, and control commands efficiently across complex architectures.

Read more
Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Understanding PLC Digital Output Types: Relay, Transistor, and Triac Explained

Programmable Logic Controllers (PLCs) form the backbone of modern industrial automation systems. They interface directly with field devices such as solenoid valves, indicator lights, motor starters, and interposing relays. Selecting the correct digital output module ensures high system availability and long hardware service life.

Read more