Skip to content

What are you looking for?


You may also like

16-Channel Analog Input 8C-PDILAI Honeywell Module16-Channel Analog Input 8C-PDILAI Honeywell Module16-Channel Analog Input 8C-PDILAI Honeywell Module
16-Channel Analog Input 8C-PDILAI Honeywell Module
16-Channel Analog Input 8C-PDILAI Honeywell Module
16-Channel Analog Input 8C-PDILAI Honeywell Module

16-Channel Analog Input 8C-PDILAI Honeywell Module


Only 10 left - Selling fast

PRODUCT SKU : 8C-PDILAI

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The Honeywell 8C-PDILAI is a high-performance analog input module designed for precise signal acquisition in demanding industrial environments. It integrates seamlessly with Honeywell’s Experion Process Knowledge System (PKS) and other Series 8 controllers, providing reliable real-time data from multiple analog sources.

Key Features

  • Supports 16 galvanically isolated analog input channels

  • Compatible with a variety of signal types including voltage (0–10 V, ±10 V, 1–5 V) and current (0–20 mA, 4–20 mA)

  • High-resolution 16-bit signal processing ensures accurate measurement

  • Exceptional stability with ±0.01% span per year

  • 500 VDC channel-to-channel isolation for safe and reliable operation

  • Fast update rate of 100 ms per channel for real-time monitoring

  • Robust environmental tolerance for –40°C to +70°C operation

Technical Specifications

  • Model Number: 8C-PDILAI

  • Channels: 16 isolated analog inputs

  • Resolution: 16 bits

  • Accuracy: ±0.1% of full scale

  • Input Impedance: Voltage >1 MΩ, Current 250 Ω

  • Update Rate: 100 ms per channel

  • Operating Temperature: –40°C to +70°C

  • Storage Temperature: –50°C to +85°C

  • Humidity: 5–95% RH, non-condensing

  • Power Supply: 24 VDC ±10%

  • Dimensions: 138 × 100 × 50 mm (5.4 × 3.9 × 2.0 in)

  • Weight: 0.5 kg (1.1 lb)

Applications

  • Data acquisition from sensors for temperature, pressure, level, and flow

  • Integration with Experion PKS or other Series 8 control systems

  • Process monitoring in chemical, oil & gas, and manufacturing facilities

  • High-reliability automation requiring isolated analog inputs

FAQ

  • Q: How many input channels does the 8C-PDILAI support?
    A: It supports 16 isolated analog input channels.

  • Q: Which signal types are compatible with this module?
    A: Voltage (0–10 V, ±10 V, 1–5 V) and current (0–20 mA, 4–20 mA).

  • Q: Can it operate in harsh industrial environments?
    A: Yes, rated for –40°C to +70°C with 500 VDC isolation and wide humidity tolerance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more