Skip to content

What are you looking for?


You may also like

10213/2/3 | Honeywell | Fail-Safe Digital Output Module10213/2/3 | Honeywell | Fail-Safe Digital Output Module10213/2/3 | Honeywell | Fail-Safe Digital Output Module
10213/2/3 | Honeywell | Fail-Safe Digital Output Module
10213/2/3 | Honeywell | Fail-Safe Digital Output Module
10213/2/3 | Honeywell | Fail-Safe Digital Output Module

10213/2/3 | Honeywell | Fail-Safe Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : 10213/2/3

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell 10213/2/3 Fail-Safe Digital Output Module is engineered for reliable signal processing in Honeywell safety and control systems. With galvanic isolation, diagnostic capabilities, and versatile contact configuration, it ensures secure and accurate digital input handling under demanding industrial conditions. Its compact design and robust specifications make it suitable for environments requiring high-speed response and fail-safe operation.

Key Features

  • Four independent digital input channels for flexible signal acquisition

  • Operates with user-supplied 18–30 VDC field power

  • Galvanic isolation between channels and backplane to prevent interference

  • Fast input response times for real-time control applications

  • Built-in diagnostics for open/short circuit detection and module health monitoring

  • Supports both Form A and Form B contact configurations

Technical Specifications

Parameter Value
Model Number 10213/2/3
Product Type Fail-Safe Digital Output Module
Power Voltage Range 18–30 VDC
Input Voltage 5–30 VDC
Input Current ≥ 3 mA
Input Impedance 4.2 kΩ
Input Response Time ≤ 5 ms
Isolation Voltage 1000 VAC RMS (system to field)
Operating Temperature –40 °C to +65 °C
Storage Temperature –40 °C to +65 °C
Humidity Range 10–90% RH, non-condensing
Dimensions 35.0 × 99.5 × 114.5 mm (W × H × D)

Application Scenarios

  • Safety-critical monitoring in distributed control systems

  • Power generation and petrochemical plants requiring fail-safe input/output modules

  • Industrial automation systems with strict diagnostic and isolation requirements

FAQ

Q: How many channels does the 10213/2/3 support?  

A: It provides four independent digital input channels.

Q: What type of isolation is implemented?

 A: Galvanic isolation between channels and the backplane ensures protection against electrical interference.

Q: Can this module detect input faults?

 A: Yes, it includes diagnostics for identifying open or short circuits and module failures.

Q: How does it compare to the Honeywell 10102/2/1 input module?  

A: While the 10102/2/1 focuses on fail-safe digital input monitoring, the 10213/2/3 emphasizes fast response and diagnostic capabilities, making it more suitable for real-time control applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more