Skip to content

What are you looking for?


You may also like

05701-A-0325 | Honeywell | DC Input Card05701-A-0325 | Honeywell | DC Input Card05701-A-0325 | Honeywell | DC Input Card
05701-A-0325 | Honeywell | DC Input Card
05701-A-0325 | Honeywell | DC Input Card
05701-A-0325 | Honeywell | DC Input Card

05701-A-0325 | Honeywell | DC Input Card


Only 10 left - Selling fast

PRODUCT SKU : 05701-A-0325

PRODUCT TYPE : Power Distribution Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for power distribution management in System 57 sub-rack enclosures, the Honeywell 05701-A-0325 (05701-A-0325) DC Input Card provides direct physical power entry and routing for rack-mounted electronics. The module accepts a nominal 24 V DC supply, distributing power via the sub-rack backplane while incorporating integrated fuse protection, RFI filtering, and reverse polarity protection for the connected control instrumentation.

Hardware Specifications

Parameter Specification
Model 05701-A-0325
Brand Honeywell
Origin Not specified
Weight 2.0 kg
Dimensions Consult System 57 technical manual
Operating Temp Consult System 57 technical manual
Power Consumption N/A (Power distribution component)
Input Type Nominal 24 V DC

Channel-to-Channel Isolation

The 05701-A-0325 utilizes internal diode-based isolation to separate the primary power supply unit (PSU) and auxiliary (AUX) standby battery inputs. This isolation architecture ensures that a voltage drop or fault in the primary supply does not back-feed into the battery backup circuit. Furthermore, the module provides RFI filtering to suppress electromagnetic noise, maintaining a clean power rail for the sensitive instrumentation across the backplane. This power conditioning is necessary to preserve the signal integrity of the control modules and prevent transient-induced errors during power state transitions.

Frequently Asked Questions

Q: Can this card be hot-swapped while the sub-rack backplane is under load?

A: No. The card must be removed or inserted only when the rack is de-energized to prevent arcing at the terminal block (TB1) or backplane connector, which could lead to power surges.

Q: How is backplane current managed when multiple catalytic cards are present?

A: In configurations exceeding eight 5704 Catalytic Cards, current load should be distributed by powering Control Cards through their associated Quad Relay Interface Cards, while using the 05701-A-0325 solely for Engineering Card power.

Field Installation Guidelines

  • Terminal Block Usage: The card features a two-part terminal block (TB1). Utilize this modular design to disconnect field wiring as a block, minimizing the need to remove individual wires during maintenance.
  • Stand-by Battery Connection: Auxiliary connections are provided for backup battery supplies. Ensure that the backup voltage polarity matches the primary supply to prevent diode conduction issues.
  • Fuse Inspection: The card incorporates an onboard fuse for overcurrent protection. Verify fuse continuity during power-up or following a rack-wide power loss.
  • Wiring Separation: Ensure that DC supply cables are routed separately from signal lines to prevent induced electromagnetic interference on the instrumentation bus.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more