The Yokogawa PW482-50, also cataloged as the PW482 Power Supply Module, operates as a dedicated hardware component for 220-240 V AC power distribution and internal rail voltage regulation within Yokogawa CENTUM VP node units.

Suffix Breakdown & Model Matrix

  • PW482: Base model designating 220-240 V AC input power supply module with extended temperature capability (-20 to 70 deg C).
  • -5: Explosion protection code designating standard type with no explosion protection.
  • 0: System configuration code designating basic type specification.

Hardware Specifications

Parameter Specification
Model PW482-50
Brand Yokogawa
Origin Japan
Input Voltage Rating 220-240 V AC
Frequency 50/60 Hz
Explosion Protection Standard type (No explosion protection)
System Code Basic type
Weight 1.0 kg (Shipping weight: 2.0 kg)
Dimensions Standard CENTUM Node Chassis Slot Assembly
Operating Temp -20 to 70 deg C
Power Consumption Accepts primary AC power to supply internal DC backplane bus

Yokogawa Power Distribution & DCS Channel-to-Channel Isolation

The power supply module converts wide-range AC utility voltage into regulated low-voltage DC backplane rails to energize local control components. Integrated galvanic isolation suppresses line transients and prevents ground loops between primary mains and downstream signal channels, supporting field I/O modules utilizing 4-20 mA HART loop protocol pairs and FOUNDATION Fieldbus communications.

Frequently Asked Questions

Q: What primary AC supply input parameters does the PW482-50 accept?

A: The module operates on a nominal input range of 220-240 V AC at 50/60 Hz to generate internal regulated DC backplane voltages.

Q: What environmental temperature limits apply to the PW482-50 hardware option?

A: This specific variant includes the extended temperature hardware build rated for operation between -20 deg C and 70 deg C.

Field Installation Guidelines

Slide the PW482-50 module into the designated power supply slot of the CENTUM node chassis until the rear connector fully seats into the backplane bus. Fasten top and bottom retaining screws to ensure proper grounding pin contact and prevent module dislodgement under physical vibration. Connect the incoming 220-240 V AC power leads to the designated terminal block, ensuring single-point protective earth (PE) grounding is maintained at the cabinet ground bar.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more