Skip to content

What are you looking for?


You may also like

Yokogawa PW482-11 | AC Input Power Supply ModuleYokogawa PW482-11 | AC Input Power Supply ModuleYokogawa PW482-11 | AC Input Power Supply Module
Yokogawa PW482-11 | AC Input Power Supply Module
Yokogawa PW482-11 | AC Input Power Supply Module
Yokogawa PW482-11 | AC Input Power Supply Module

Yokogawa PW482-11 | AC Input Power Supply Module


Only 10 left - Selling fast

PRODUCT SKU : PW482-11

PRODUCT TYPE : Power Supply Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The PW482-11 (Order No. PW482) from Yokogawa is a high-performance AC input power supply module engineered for industrial environments requiring stable and reliable power distribution. Designed with durability and operational flexibility in mind, this module ensures consistent performance across a wide temperature range and demanding conditions.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model: PW482-11

  • Product Type: Power Supply Module

  • Input Voltage: 220–240 VAC

  • Operating Temperature Range: -20°C to +70°C (extended option)

  • Standard Temperature Range: 0°C to +70°C

  • Weight: 5 kg

  • Suffix Codes:

    • -5: Standard type, no explosion protection

    • -E: Explosion-protected type

    • 0: Basic type

    • 1: ISA Standard G3 compliant option

Key Features

  • Robust AC input design for stable power delivery

  • Extended operating temperature option for harsh environments

  • Multiple suffix configurations for application-specific requirements

  • Compact and durable construction suitable for industrial automation systems

Application Scenarios

  • Distributed control systems (DCS) in process industries

  • Power supply for instrumentation modules in chemical plants

  • Reliable energy source for monitoring and control equipment in oil & gas facilities

  • Industrial automation systems requiring explosion-protected configurations

FAQ

Q: What is the difference between PW482-10 and PW482-11?  A: The PW482-11 offers an extended operating temperature range (-20°C to +70°C), making it more suitable for extreme environments compared to the PW482-10.

Q: Can the PW482-11 be used in hazardous areas?  A: Yes, the suffix code -E provides explosion protection for hazardous industrial settings.

Q: What standards does the PW482-11 comply with?  A: The suffix code 1 ensures compliance with ISA Standard G3 for environments with corrosive gases.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more
Optimizing Power Supply Sizing for Industrial Automation Systems

Optimizing Power Supply Sizing for Industrial Automation Systems

The power supply is the silent heartbeat of any industrial automation system. While engineers often prioritize processors and communication protocols, a stable power architecture remains the most critical factor for long-term reliability. In my 15 years of experience, I have found that neglecting power supply sizing often leads to ghost errors, intermittent field device failures, and costly production downtime.

Read more