Skip to content

What are you looking for?


You may also like

ZR402G-T-E-E-A/H/SCT | Yokogawa | Separate type Zirconia Oxygen Analyzer, ConverterZR402G-T-E-E-A/H/SCT | Yokogawa | Separate type Zirconia Oxygen Analyzer, ConverterZR402G-T-E-E-A/H/SCT | Yokogawa | Separate type Zirconia Oxygen Analyzer, Converter
ZR402G-T-E-E-A/H/SCT | Yokogawa | Separate type Zirconia Oxygen Analyzer, Converter
ZR402G-T-E-E-A/H/SCT | Yokogawa | Separate type Zirconia Oxygen Analyzer, Converter
ZR402G-T-E-E-A/H/SCT | Yokogawa | Separate type Zirconia Oxygen Analyzer, Converter

ZR402G-T-E-E-A/H/SCT | Yokogawa | Separate type Zirconia Oxygen Analyzer, Converter


Only 10 left - Selling fast

PRODUCT SKU : ZR402G-T-E-E-A/HS/SCT

PRODUCT TYPE : Oxygen Analyzer Converters

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Yokogawa ZR402G-T-E-E-A/H/SCT, also cataloged as the ZR402G Separate type Zirconia Oxygen Analyzer, Converter, operates as a dedicated hardware component for continuous gas phase oxygen concentration signal processing within Yokogawa process automation networks.

Suffix Breakdown & Model Matrix

The Yokogawa ZR402G oxygen analyzer converter uses a structured order option code matrix to specify thread entry interfaces, display languages, protective hardware, and physical tagging.

Suffix / Option Specification & Hardware Definition
ZR402G Base model converter for separate-type zirconia oxygen measurement systems
-T Conduit thread connection: 1/2 NPT
-E Display language interface: English
-E Instruction manual documentation: English
-A Standard functional revision: Always -A
/H Hardware Option: Protective rain and sun hood
/SCT Material Tagging Option: Stainless steel tag plate

Hardware Specifications

Parameter Specification
Model ZR402G-T-E-E-A/H/SCT
Brand Yokogawa
Origin Japan
Weight Approx. 6 kg (Shipping weight 10 kg)
Dimensions Standard enclosure sizing for panel/wall/pipe mounting
Operating Temp -20 to 55 deg C
Power Consumption Max 300 W (Approx 100 W nominal operation)
Display Type 320 x 240 dot matrix LCD screen with integrated touchscreen
Analog Output Signal Two-point 4-20 mA DC (Maximum load resistance 550 ohm)
Contact Output Signal Four points (Includes one fail-safe normally open contact)
Contact Input Two points
Analog Input One point (4-20 mA temperature/process input)
Power Supply Voltage Rated 100 to 240 VAC (Operating range 85 to 264 VAC)
Ambient Humidity 0 to 95% RH (non-condensing)
Cable Conduit Entries Eight entry ports (1/2 NPT interface configured)
Enclosure Material Aluminum alloy with polyurethane corrosion-resistant finish

Process Control & DCS Instrument Characteristics

The ZR402G converter processes raw millivolt electromotive force (EMF) signals generated by remote zirconia oxygen detectors. Operating across a dual 4-20 mA HART loop protocol layer, the unit provides high channel-to-channel isolation between internal AC power supplies, detector heater drives, and low-level analog I/O loops. The hardware incorporates automated dynamic cold junction compensation (CJC) algorithms and sensor diagnostics to track cell resistance and probe response decay. Isolated contact inputs and relay outputs execute automated calibration sequence timing, fault signaling, and blowback purges in coordination with main distributed control systems.

Frequently Asked Questions

Q: How is the fail-safe contact output configured inside the ZR402G unit?

A: The converter incorporates four total contact outputs, one of which is specifically configured as a fail-safe relay with a normally open (NO) contact configuration. Upon total loss of AC power supply or critical internal processor fault, this contact drops out to signal an immediate hardware failure state to the DCS.

Q: What load resistance limits apply to the dual isolated 4-20 mA analog outputs?

A: Each 4-20 mA DC current output channel supports a maximum external loop load resistance of 550 ohm. Exceeding 550 ohm causes signal clipping and degrades communication stability when HART field devices or line recorders are connected in series.

Field Installation Guidelines

  1. Mount the aluminum alloy housing securely to a 2-inch vertical/horizontal pipe, flat panel, or wall using approved mounting brackets. Ensure the rain hood (/H) is correctly fitted over the top casing when exposed to outdoor environments.
  2. Maintain a minimum thread engagement of 5 full 1/2 NPT thread turns on all electrical conduit connections. Seal unused conduit holes with the provided 1/2 NPT threaded plugs to preserve enclosure weatherproofing.
  3. Route low-voltage zirconia sensor signal wires and AC power lines in separate grounded metal conduits to prevent inductive noise interference with cell EMF measurements.
  4. Ground the main internal and external enclosure chassis lugs to a dedicated low-impedance earth ground point (less than 10 ohm ground resistance).
  5. Ensure operating AC supply voltage remains strictly within 85 to 264 VAC before powering on the converter touchscreen interface.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.