Product Details

Product Overview

The Yokogawa YCB111-M025 serves as the heavy-duty communication backbone for Yokogawa Distributed Control Systems (DCS). This 25-meter industrial coaxial cable facilitates high-speed data transmission across V net and ER bus layers, linking system cabinets and remote I/O nodes with deterministic precision. We supply this unit as 100% Brand New and Original, ensuring your network maintains zero packet loss in environments characterized by severe electromagnetic interference.

Part Number Breakdown

Code Specification Description
YCB111 Model Series 10BASE-5 Thick Coaxial Cable for DCS
-M025 Length Suffix 25 Meters (approx. 82 feet) fixed length

Technical Specifications

Feature Details
Protocol Standard IEEE 802.3 10BASE-5 (Thick Ethernet)
Cable Length 25 Meters
Network Support V net, ER bus, ESB bus, RIO bus
Interface Design Solderless connectors for M4 screw terminals
Shielding High-density EMI/RFI braid
Bend Radius 100 mm minimum (permanent installation)
Temperature Range -20°C to +70°C
Jacket Material Industrial-grade flame-retardant polymer

Engineering Advantages

  • Superior Backbone Integrity: The YCB111-M025 utilizes 10BASE-5 "Thick Ethernet" technology, which offers significantly lower signal attenuation compared to the thinner YCB141 series. This makes it the superior choice for primary trunk lines between critical DCS nodes.

  • Solderless Termination Logic: The cable features integrated solderless connectors designed for M4 screw terminals. This engineering choice allows field technicians to secure connections rapidly without specialized soldering tools, effectively lowering the Mean Time to Repair (MTTR) during system maintenance.

  • Extreme Noise Immunity: A high-density EMI/RFI braid encases the inner conductor, neutralizing the effects of magnetic fields generated by nearby high-voltage motors or switchgear. This shielding ensures that process data remains synchronized without jitter.

  • Mechanical Resilience: The flame-retardant outer jacket protects the core against chemical exposure and thermal stress. The specified 100 mm bend radius allows for clean routing through industrial cable trays while preventing internal dielectric deformation.

FAQs

  • Can I use the YCB111-M025 to replace a YCB141 cable?

    The YCB111-M025 uses a 10BASE-5 standard, whereas the YCB141 typically follows 10BASE-2 (Thin Ethernet). While they serve similar network architectures like V net, they require different connector types (Screw terminal vs. BNC). Verify your hardware interface before switching models.

  • How does this cable improve system reliability in high-vibration areas?

    The solderless M4 screw terminal design provides a mechanical lock that resists loosening better than standard snap-on connectors. This ensures continuous contact in refinery or power plant environments where machinery vibration is constant.

  • What is the maximum distance supported by this cable type?

    As a 10BASE-5 cable, it supports longer individual segments than thin coaxial alternatives. For runs exceeding 25 meters, you can interconnect multiple YCB111 segments using approved Yokogawa bus repeaters or joiners to maintain signal strength.

  • Is this cable suitable for ProSafe-RS safety networks?

    Yes. The YCB111-M025 provides the physical layer required for both Centum VP and ProSafe-RS safety instrumented systems (SIS), ensuring high-availability communication for safety-critical loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more