Skip to content

What are you looking for?


You may also like

5464-334 Isolated 4-20mA Analog Input 8 Channel Module | Woodward5464-334 Isolated 4-20mA Analog Input 8 Channel Module | Woodward5464-334 Isolated 4-20mA Analog Input 8 Channel Module | Woodward
5464-334 Isolated 4-20mA Analog Input 8 Channel Module | Woodward
5464-334 Isolated 4-20mA Analog Input 8 Channel Module | Woodward
5464-334 Isolated 4-20mA Analog Input 8 Channel Module | Woodward

5464-334 Isolated 4-20mA Analog Input 8 Channel Module | Woodward


Only 10 left - Selling fast

PRODUCT SKU : 5464-334

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-precision analog signal acquisition in turbine control platforms, the Woodward 5464-334 (5464-334 Analog Input Module) provides direct physical execution of isolated 4-20 mA current loop sensing and onboard diagnostic processing.

Hardware Specifications

Parameter Specification
Model 5464-334
Brand Woodward
Origin USA
Weight 0.8 kg
Dimensions 30 cm x 20 cm x 25 cm
Operating Temp -25 deg C to +70 deg C
Power Consumption 10-60 VDC
Channels 8 Channels
Isolation 3000 VDC

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The 5464-334 module utilizes an intelligent microcontroller architecture to manage 8 independent 4-20 mA input channels. Each channel maintains galvanic isolation to suppress common-mode noise and prevent cross-channel interference. To maintain signal integrity during continuous operation, the module's circuitry is engineered with specific thermal heat sink dissipation profiles, preventing localized overheating in the high-density terminal interface. This thermal management supports consistent actuator loop feedback response, as the module performs automated temperature compensation and calibration by periodically measuring an onboard precision voltage reference. The module independently handles rate-group scheduling, minimizing the processing overhead on the central CPU while ensuring deterministic signal acquisition and fault reporting.

Frequently Asked Questions

Q: How does the module handle internal fault detection for individual input channels?

A: The onboard microcontroller executes power-on self-tests and continuous background diagnostics. If a channel deviation is detected relative to the internal voltage reference or if an electrical fault occurs, the module illuminates the front-panel LED to signal the fault state to the operator.

Q: Is the 3000 VDC isolation rating applied channel-to-channel or channel-to-chassis?

A: The 3000 VDC isolation specification defines the dielectric strength between the input circuitry and the system ground/backplane. This level of isolation ensures that transients on the field side do not propagate to the control-side communication bus.

Field Installation Guidelines

  • Mounting: Secure the module within the designated control rack, ensuring positive engagement with the backplane connectors. Verify that the cabinet environment remains within the -25 to +70 deg C range.
  • Wiring: Terminate field loops using shielded, twisted-pair cabling. Maintain strict polarity for all 4-20 mA inputs to ensure correct transducer signal interpretation.
  • Grounding: Connect cable shields to the cabinet ground bus at a single common point. Avoid multiple ground paths for the shield to prevent the induction of circulating currents that may interfere with the current loop precision.
  • Power-up Procedure: Energize the control rack and observe the front-panel LED. Successful initialization occurs when the LED extinguishes following the completion of the onboard microcontroller self-tests.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more