Skip to content

What are you looking for?


You may also like

Triconex 3604E Tricon Digital Output ModuleTriconex 3604E Tricon Digital Output ModuleTriconex 3604E Tricon Digital Output Module
Triconex 3604E Tricon Digital Output Module
Triconex 3604E Tricon Digital Output Module
Triconex 3604E Tricon Digital Output Module

Triconex 3604E Tricon Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : 3604Е

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : Triconex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Triconex 3604E (also referenced under ordering number 3640E) is a 16-point digital output module engineered for the Tricon Triple Modular Redundancy (TMR) safety platform. Operating at a nominal system voltage of 24 VDC, it converts controller safety logic into discrete output signals to drive field-side final elements.

Output Performance and Load Characteristics

The module features 16 non-commoned, point-isolated output channels designed to operate across a field voltage range of 22-45 VDC. Each point supports a maximum continuous load current of 2 A, with a surge capability of 10 A for 10 ms. To protect module electronics, field terminations utilize one 2.5 A fast-acting fuse per output point.

Electrical Isolation and Hardware Identification

With a 1500 VDC point-to-point isolation rating, the unit prevents electrical transients from propagating across channels or back to the control system. The physical front panel incorporates a dark blue color code for quick identification in Tricon chassis slots.

Parameter Specification
Model 3604E (3640E)
Brand Triconex
Product Category Digital Output Modules
System Architecture Triple Modular Redundant (TMR)
Number of Output Points 16, non-commoned
Nominal Voltage 24 VDC
Operating Voltage Range 22-45 VDC
Maximum Continuous Current 2 A per point
Surge Current 10 A per point for 10 ms
Typical Voltage Drop < 4 V
Load Leakage Current 2 mA maximum
Point Isolation 1500 VDC
Field Termination Fuses 1 per output, 2.5 A fast-acting
Color Code Dark blue
Shipping Weight 5 kg

Frequently Asked Questions

Q: What fusing protection is required for field outputs on the Triconex 3604E?

A: Field termination assemblies use individual 2.5 A fast-acting fuses allocated to each of the 16 output points.

Q: What are the current and surge ratings for each channel on this module?

A: Each point supports a maximum continuous load rating of 2 A, with an allowable surge current of up to 10 A for a 10 ms duration.

Q: How are the output channels isolated from each other?

A: The module provides 16 non-commoned outputs with point-to-point electrical isolation rated at 1500 VDC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more