The Honeywell XNXXSR1SS, also cataloged as the XNXXSR1SS Smart Sensor Cartridge, operates as a dedicated hardware component for continuous Hydrogen Chloride (HCl) gas detection and toxic gas signal processing within XNX Universal Gas Detector platforms.

Hardware Specifications

Parameter Specification
Model XNXXSR1SS
Brand Honeywell
Origin USA
Weight 5.0 kg (11.0 lbs)
Dimensions Standard XNX transmitter sensor socket footprint
Operating Temp -40 to +65 deg C
Power Consumption Transmitter-supplied loop power
Detected Gas Hydrogen Chloride (HCl)
Analog Output Config User-selectable source, sink, or isolated 4-20 mA
Sensor Interface Factory-calibrated plug-and-play smart cartridge
Calibration Type Automatic calibration with auto-inhibit status
Ingress Protection IP66

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The smart sensor cartridge interfaces directly with the main XNX transmitter backplane via pre-calibrated digital bus connections. The selectable isolated 4-20 mA analog output stage incorporates internal channel-to-channel galvanic isolation barriers, preventing ground loop potential differentials and noise insertion across long cable runs. The transmitter maintains full 4-20 mA HART protocol communication capability, allowing remote configuration, diagnostic status polling, and continuous toxic gas concentration readout at the host DCS interface.

Frequently Asked Questions

Q: Does the XNXXSR1SS sensor cartridge require field gas calibration immediately upon installation?

A: No, the module arrives factory-calibrated as a plug-and-play assembly, utilizing an automatic calibration sequence with auto-inhibit to prevent false alarm trips during initial replacement.

Q: What analog current signal output modes can be configured on the transmitter host?

A: The transmitter analog output stage supports three selectable wiring modes: current source, current sink, or fully isolated 4-20 mA output configurations.

Field Installation Guidelines

  1. Isolate loop power to the XNX transmitter enclosure before threading or replacing the sensor cartridge.
  2. Insert the smart sensor cartridge into the designated transmitter socket, ensuring full engagement of mechanical locking keys.
  3. Verify that the housing seal engages properly to maintain the overall IP66 ingress protection rating against moisture and dust ingress.
  4. Ground all cable shield drain wires at the main controller cabinet earth bar to preserve signal integrity against external electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more