The Honeywell SPXCDXSFXSS, also cataloged as the SPXCDXSFXSS Replacement XCD Sensor Cartridge, operates as a dedicated hardware component for catalytic bead flammable gas detection within Sensepoint XCD transmitter systems.

Hardware Specifications

Parameter Specification
Model SPXCDXSFXSS
Brand Honeywell
Origin USA
Weight 3.0 kg (Shipping weight)
Dimensions Standard Sensepoint XCD socket dimensions
Operating Temp -40 to 65 deg C
Power Consumption Powered via Sensepoint XCD transmitter base
Sensor Type Catalytic Bead (Pellistor) Flammable Gas Sensor
Measurement Range 0 to 100% LEL (Configurable 20 to 100% LEL in 10% LEL steps)
Target Gases Flammable hydrocarbon gases and vapors
Enclosure Material 316 Stainless Steel barrel housing

4-20 mA HART Loop Protocol and Channel Isolation

The SPXCDXSFXSS plug-in sensor cartridge interfaces directly with the Sensepoint XCD transmitter mainboard via a keyed socket connection. Active signal processing inside the transmitter conditions the raw catalytic millivolt output into a linear 4-20 mA HART loop protocol signal. Internal channel-to-channel isolation prevents electrical ground loops between field sensors and central DCS controllers, shielding sensitive catalytic measurement circuits against common-mode noise and electromagnetic interference in industrial control loops.

Frequently Asked Questions

Q: Is hot-swapping the SPXCDXSFXSS sensor cartridge permitted in hazardous field locations?

A: No. Power to the Sensepoint XCD transmitter transmitter housing must be isolated or the area verified as non-hazardous prior to unscrewing the sensor locking ring and replacing the cartridge.

Q: Does the SPXCDXSFXSS cartridge require manual calibration upon initial insertion into the transmitter base?

A: Yes. Following mechanical installation, zero and span calibration procedures must be executed using target test gas to match the transmitter baseline to the specific cartridge response curve.

Field Installation Guidelines

  1. Isolate primary field power to the Sensepoint XCD transmitter housing before servicing the sensor assembly.
  2. Loosen the hex socket locking grub screw on the transmitter sensor socket cover.
  3. Unscrew the retaining ring and remove the depleted sensor cartridge from the keyed internal header.
  4. Align the locator pins of the replacement SPXCDXSFXSS cartridge with the transmitter socket and insert firmly until fully seated.
  5. Thread the outer locking ring securely back onto the housing, ensuring the weatherproof flameproof seal engages properly, and tighten the grub screw.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more