The Honeywell LG1093AA26, also cataloged as the LG1093 Flame Sensor, operates as a dedicated hardware component for direct ultraviolet optical radiation sensing and combustion flame detection within burner monitoring systems. Physical mounting through a 3/4 inch internal NPT connection interfaces directly with sight pipes to monitor combustion intensity. Electrical signals translate through a Teflon shielded cable to communicate flame state feedback directly to control panels.

Hardware Specifications

Parameter Specification
Model LG1093AA26
Brand Honeywell
Origin USA
Weight 4.00 kg
Dimensions Standard Optical Housing Assembly
Operating Temp -40 to +176 deg C (-40 to +350 deg F)
Power Consumption Passive Sensing Element
Sensor Type Optical Flame Sensor
Mounting Interface 3/4 inch internal NPT
Control Connection Teflon shielded cable with 1 inch external conduit thread
Pressure Rating 150 psig at 204 deg C (400 deg F) window rating
Cable Length 61 ft (18.6 m)

Channel-to-Channel Isolation

The LG1093AA26 sensor assembly incorporates signal isolation via a Teflon shielded cable harness to prevent signal degradation and cross-talk across adjacent sensor channels. Shielding suppresses electromagnetic interference from high-voltage ignition spark transformers and adjacent electrical drives. High dielectric isolation safeguards control panel inputs against field ground loops and common-mode transients occurring along the sight pipe housing.

Frequently Asked Questions

Q: Can the LG1093AA26 flame sensor be serviced or disconnected while the combustion chamber is pressurized?

A: No. The viewing window maintains a 150 psig pressure rating at 204 deg C. The process line must be depressurized and isolated before removing the sensor from its 3/4 inch NPT mounting thread.

Q: How is signal shielding maintained along the 61 ft cable run to the control panel?

A: The Teflon shielded cable uses an integrated shield conductor connected through a 1 inch external conduit thread to maintain low-impedance grounding and noise suppression.

Q: What is the operating temperature threshold for the sensor electronics and housing?

A: The sensor housing and internal optics are rated for continuous operational exposure between -40 and +176 deg C (-40 to +350 deg F).

Field Installation Guidelines

  1. Inspect the 3/4 inch internal NPT mounting threads and clean the sight pipe opening prior to installation.
  2. Engage the mounting thread with a minimum of 5 full turns of thread engagement, applying high-temperature thread sealant as required.
  3. Route the Teflon shielded cable through a 1 inch conduit, maintaining separation from high-voltage ignition leads and AC power cables.
  4. Verify window glass seal integrity to prevent hot combustion gas bypass under process pressures up to 150 psig.
  5. Connect the cable shield drain wire directly to the control panel earth ground bus bar.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more