Skip to content

What are you looking for?


You may also like

Emerson Epro PR6423/011-110-CN & CON021 Eddy Current Sensor SystemEmerson Epro PR6423/011-110-CN & CON021 Eddy Current Sensor SystemEmerson Epro PR6423/011-110-CN & CON021 Eddy Current Sensor System
Emerson Epro PR6423/011-110-CN & CON021 Eddy Current Sensor System
Emerson Epro PR6423/011-110-CN & CON021 Eddy Current Sensor System
Emerson Epro PR6423/011-110-CN & CON021 Eddy Current Sensor System

Emerson Epro PR6423/011-110-CN & CON021 Eddy Current Sensor System


Only 10 left - Selling fast

PRODUCT SKU : CON021+PR6423/011-110-CN

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-frequency displacement measurement in turbomachinery monitoring systems, the Emerson Epro PR6423/011-110-CN (PR6423/011-110-CN) transducer paired with the CON021 signal converter provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model PR6423/011-110-CN + CON021
Brand Emerson Epro
Origin Germany
Weight 0.12 kg (Converter)
Dimensions Standard probe housing and converter geometry
Operating Temp -30 deg C to +100 deg C (Converter); -35 deg C to +180 deg C (Sensor)
Power Consumption -23 VDC to -32 VDC
Measuring Range 2.0 mm

Gap Voltage Validation (-10 VDC targets)

The system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.

Frequently Asked Questions

Q: Does the CON021 signal converter support hot-swap replacement in a monitoring rack?

A: Yes, the CON021 is designed for integration into monitoring racks where it supports replacement while the system is energized, provided the rack backplane architecture supports hot-swapping.

Q: Is the IP20 rating of the CON021 suitable for direct skid mounting?

A: No. The IP20 protection class mandates installation within a protective enclosure, control cabinet, or junction box to prevent exposure to environmental contaminants, moisture, or metallic debris.

Field Installation Guidelines

  1. Mount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.
  2. Ensure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.
  3. Set the nominal air gap at 0.5 mm using a non-metallic feeler gauge to prevent contact damage to the sensor tip.
  4. Route signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.
  5. Terminate the signal shield at the monitoring system (DCS/TSI) rack only to prevent ground-loop current injection into the converter circuit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more