Emerson CON041-CN+PR6423/000-031 Proximity Sensors
Emerson CON041-CN+PR6423/000-031 Proximity Sensors

Emerson CON041-CN+PR6423/000-031 Proximity Sensors


Only 10 left - Selling fast

PRODUCT SKU : CON041-CN+PR6423/000-031

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Emerson CON041-CN+PR6423/000-031, also cataloged as the CON041-CN / PR6423 Proximity Sensors, operates as a dedicated hardware component for non-contact shaft vibration, position, and eccentricity measurement within Emerson MMS 6000 and MMS 3000 platforms. The hardware system links an 8 mm inductive proximity probe with the CON041-CN signal converter module to evaluate spatial displacement against conductive ferromagnetic targets. High-frequency oscillator fields convert dynamic surface gap deviations directly into linear continuous voltage or current signals without physical mechanical wear.

Hardware Specifications

Parameter Specification
Model CON041-CN+PR6423/000-031
Brand Emerson
Origin United States
Operating Temp -35 to +180 deg C (Sensor) / -35 to +150 deg C (Cable)
Power Consumption Standard loop power (24 VDC supply)
Supply Voltage 24 VDC
Measurement Range Typically +/-2 mm peak-to-peak; linear up to 4 mm
Sensitivity 8 V/mm (203.2 mV/mil) +/-5%
Frequency Range 0 to 20000 Hz (-3 dB)
Output Signal Analog voltage (0-10 V) or current (4-20 mA)
Target Material Ferromagnetic steel (e.g., 42CrMo4)
Ingress Protection IP65

4-20 mA HART Loop Protocol & Channel Isolation

The CON041-CN signal converter incorporates high-speed conditioning circuitry with a < 15 us rise time to support broad dynamic frequency ranges up to 20000 Hz. The signal path provides continuous channel-to-channel isolation to prevent potential differences between adjacent sensor loops from introducing noise into process monitoring circuits. Configured for standardized 4-20 mA HART loop protocol signaling alongside direct voltage modes, the driver compensates for thermal variations across the -35 to +180 deg C range to maintain exact scale factor linearity.

Frequently Asked Questions

Q: How is the CON041-CN converter secured in control cabinets?

A: The converter module utilizes a standardized DIN rail mounting chassis for direct snap-on installation within industrial control enclosure racks.

Q: What target surface material is required for the PR6423 sensor calibration?

A: The sensor sensitivity of 8 V/mm is factory-calibrated for ferromagnetic steel targets, such as 42CrMo4 steel shafts.

Field Installation Guidelines

Maintain an unobstructed lateral clearance zone around the 8 mm probe tip equal to at least 1.5 times the tip diameter to eliminate uncalibrated side-wall interference from metallic surroundings. Mount the CON041-CN converter securely onto a standard DIN rail inside a protective enclosure. Route sensor extension leads through dedicated grounded metallic conduit, keeping signal paths physically separated from high-voltage AC feeds or motor drive connections. Connect all cable shields to technical functional earth at a single point only to prevent circulating ground currents.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.