Skip to content

What are you looking for?


You may also like

Emerson CON021+PR6423/010-100 EPRO Eddy Current Signal Converter and Sensor SystemsEmerson CON021+PR6423/010-100 EPRO Eddy Current Signal Converter and Sensor SystemsEmerson CON021+PR6423/010-100 EPRO Eddy Current Signal Converter and Sensor Systems
Emerson CON021+PR6423/010-100 EPRO Eddy Current Signal Converter and Sensor Systems
Emerson CON021+PR6423/010-100 EPRO Eddy Current Signal Converter and Sensor Systems
Emerson CON021+PR6423/010-100 EPRO Eddy Current Signal Converter and Sensor Systems

Emerson CON021+PR6423/010-100 EPRO Eddy Current Signal Converter and Sensor Systems


Only 10 left - Selling fast

PRODUCT SKU : CON021+PR6423/010-100

PRODUCT TYPE : Eddy Current Signal Converter and Sensor Systems

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-frequency dynamic displacement and position execution in machinery monitoring networks, the Emerson CON021+PR6423/010-100 (CON021+PR6423/010-100 Eddy Current Signal Converter and Sensor Systems) provides direct physical signal conditioning. The converter and probe assembly converts proximity variations across rotating shafts into linear output voltages for machinery protection loops.

Hardware Specifications

Parameter Specification
Model CON021+PR6423/010-100
Brand Emerson
Origin USA / Germany
Weight ~120 grams (Converter module mass)
Dimensions Housing material LMgSi 0.5 F22 (Converter); 100 mm case thread length (Probe)
Operating Temp Sensor: -35 to +180 deg C; Cable: -35 to +150 deg C; Converter: -30 to +100 deg C
Power Consumption Powered via -21 VDC to -32 VDC supply rail
Supply Voltage Range -23 V to -32 V (Output Range -4 V to -20 V); -21 V to -32 V (Output Range -2 V to -18 V)
Linear Range 2 mm (80 mils) baseline standard span
Frequency Range (-3 dB) 0 to 20000 Hz
Rise Time Less than 15 us
Protection Class Sensor: IP66 (IEC 60529); Converter: IP20
Signal Connections Screw terminal type (max 1.5 mm2 wire)
Product Type Eddy Current Signal Converter and Sensor Systems

4-20 mA HART Loop Protocol and Channel Isolation

The CON021 converter processing path uses channel-to-channel isolation architecture to isolate primary probe measurement circuits from backplane supply rails. When integrated alongside plant control systems operating 4-20 mA HART loop protocol instruments or FOUNDATION Fieldbus signal splitters, the system maintains linear voltage accuracy across dynamic frequencies up to 20000 Hz. Built-in thermal compensation circuits continuously mitigate gain shifts, providing cold junction compensation stability and drift suppression over wide operating temperatures.

Frequently Asked Questions

Q: What power supply rail range must be supplied to the CON021 converter for a standard -4 V to -20 V output signal span?

A: The CON021 signal converter requires an incoming DC supply voltage between -23 VDC and -32 VDC to produce a full -4 V to -20 V linear output range.

Q: Can the PR6423 probe head be exposed to high-temperature machinery environments?

A: Yes, the PR6423 probe head and initial 1 m integral cable section are rated for operation in ambient temperatures ranging from -35 to +180 deg C.

Q: What is the maximum wire size allowed for signal and power wiring on the CON021 terminal block?

A: The supply and signal output screw terminals support stranded or solid copper conductors up to a maximum cross-sectional area of 1.5 mm2.

Field Installation Guidelines

  1. Mount the CON021 converter module in a clean enclosure rated for at least IP20, secured via four M5 mounting screws.
  2. Thread the 100 mm case length PR6423 probe into the machine casing bracket perpendicular to the target shaft.
  3. Establish the target air gap by adjusting probe insertion depth to match baseline static DC gap voltage specifications before locking the jam nut.
  4. Route probe cabling through dedicated grounded metallic conduit away from high-voltage motor feeds and variable frequency drives.
  5. Connect input signal wires from the probe extension cable to the CON021 input connector block.
  6. Connect supply and output field wiring to the CON021 screw terminals, ensuring wire size does not exceed 1.5 mm2 and the cable shield is tied to single-point cabinet ground.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more