CON031+PR6423/000-101 Emerson EPRO Eddy Current Signal Converter and Sensor Systems
CON031+PR6423/000-101 Emerson EPRO Eddy Current Signal Converter and Sensor Systems
CON031+PR6423/000-101 Emerson EPRO Eddy Current Signal Converter and Sensor Systems

CON031+PR6423/000-101 Emerson EPRO Eddy Current Signal Converter and Sensor Systems


Only 10 left - Selling fast

PRODUCT SKU : CON031+PR6423/000-101

PRODUCT TYPE : Eddy Current Signal Converter and Sensor Systems

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-frequency dynamic displacement signal processing in machinery monitoring networks, the Emerson CON031+PR6423/000-101 (CON031+PR6423/000-101 Eddy Current Signal Converter and Sensor Systems) provides direct physical signal conditioning and electromagnetic gap execution. The converter and probe assembly processes shaft position shifts into high-linearity analog voltage signals across rotating equipment protection loops.

Hardware Specifications

Parameter Specification
Model CON031+PR6423/000-101
Brand Emerson
Origin Germany
Operating Temp Sensor: -35 to +180 deg C (head/1 m cable), Cable: -35 to +150 deg C, Converter: -30 to +100 deg C
Power Consumption Power supplied via rack monitor backplane or external supply
Frequency Range (-3 dB) 0 to 20000 Hz
Rise Time Less than 15 us
Sensor Cable Length 4.0 m
Cable Termination Open cable end
Minimum Shaft Diameter 25 mm (0.79 in)
Standard Target Material Ferromagnetic Steel 42CrMo4 (AISI/SAE 4140)
Protection Class Sensor: IP66 (IEC 60529); Converter: IP20
Compatibility CON031 compatible with PR6422, PR6423, PR6424, PR6426
Product Type Eddy Current Signal Converter and Sensor Systems

4-20 mA HART Loop Protocol and Channel Isolation

The CON031 signal converter utilizes channel-to-channel isolation architecture to prevent common-mode ground noise from invalidating wide-bandwidth vibration data across the 0 to 20000 Hz frequency range. When interfaced with process automation networks operating 4-20 mA HART loop protocol instruments or FOUNDATION Fieldbus nodes, the converter keeps signal conditioning circuits galvano-isolated from main plant supply buses. Internal thermal compensation circuits manage temperature shifts, stabilizing cold junction compensation references and ensuring precise dynamic response during rapid thermal transients.

Frequently Asked Questions

Q: Can the CON031 converter be paired with a PR6425 probe for extended range applications?

A: No, the PR6425 probe strictly requires an extended range signal converter such as the CON021/91x-xxx series to match its calibration envelope.

Q: What precautions must be observed regarding the open cable end on the PR6423/000-101 probe?

A: The open cable end must be properly landed in a terminal block with outer shield wire grounded at one point inside an IP-rated junction box to prevent RF noise coupling.

Q: How does target material composition impact the output calibration of the CON031 converter?

A: The system is factory calibrated to Ferromagnetic Steel 42CrMo4 (AISI/SAE 4140). Using alternative shaft alloys alters magnetic permeability and requires recalibration of the scale factor.

Field Installation Guidelines

  1. Mount the CON031 signal converter onto a 35 mm DIN rail inside a protective enclosure, maintaining an IP20 environment and operating temperatures between -30 and +100 deg C.
  2. Inspect the target rotor shaft to verify a minimum shaft diameter of 25 mm and confirm material specification matches 42CrMo4 ferromagnetic steel.
  3. Mount the PR6423 probe head perpendicular to the shaft, maintaining correct thread engagement for the 25 mm case length.
  4. Adjust insertion depth to set the static mechanical air gap according to system baseline DC voltage specifications before tightening the outer locknut.
  5. Connect the 4.0 m open-ended cable conductors to the CON031 input terminals, ensuring the cable shield terminates at a single-point cabinet ground.
  6. Route all probe signal cables in dedicated metallic conduit isolated from high-voltage AC motor cables.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more