Skip to content

What are you looking for?


You may also like

CON021+PR6423/017-030-CN Eddy Current Sensor System | EmersonCON021+PR6423/017-030-CN Eddy Current Sensor System | EmersonCON021+PR6423/017-030-CN Eddy Current Sensor System | Emerson
CON021+PR6423/017-030-CN Eddy Current Sensor System | Emerson
CON021+PR6423/017-030-CN Eddy Current Sensor System | Emerson
CON021+PR6423/017-030-CN Eddy Current Sensor System | Emerson

CON021+PR6423/017-030-CN Eddy Current Sensor System | Emerson


Only 10 left - Selling fast

PRODUCT SKU : CON021+PR6423/017-030-CN

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Emerson CON021+PR6423/017-030-CN, also cataloged as the CON021+PR6423 Eddy Current Sensor System, operates as a dedicated hardware component for continuous shaft vibration signal conditioning and displacement measurement within Ovation DCS platforms.

Hardware Specifications

Parameter Specification
Model CON021+PR6423/017-030-CN
Brand Emerson
Origin USA
Operating Temp -35 deg C to +180 deg C (Probe head)
Power Consumption Loop-powered via DCS analog interface / converter module
Loop Protocol 4-20 mA HART loop protocol / raw analog displacement signal
Probe Cable Length 17 m (-017 suffix variant)
Channel Isolation Galvanic channel-to-channel isolation on controller stage

4-20 mA HART Loop Protocol and Channel Isolation

The CON021 signal converter processes high-frequency eddy-current fluctuations from the PR6423 probe into calibrated analog signals. Utilizing a 4-20 mA HART loop protocol structure, the electronics driver delivers linear real-time vibration data directly to downstream Ovation controller field interface modules. Channel-to-channel isolation prevents electrical ground loops and cross-talk noise between adjacent radial measurement axes, ensuring continuous signal integrity and high signal-to-noise ratios across harsh field environments.

Frequently Asked Questions

Q: What does the suffix "017-030-CN" specify in the hardware configuration?

A: The suffix designates an integrated 17 m cable length (-017) along with a "030-CN" regional mechanical and regulatory compliance variant for industrial installations.

Q: Is the CON021 converter module restricted exclusively to the PR6423/017-030-CN probe model?

A: No, the CON021 signal processing interface supports matching parameters across multiple EPRO eddy-current probe series, provided the total electrical system length matches system tuning requirements.

Field Installation Guidelines

  • Ensure proper grounding of the cable shield at the DCS cabinet terminal strip to eliminate ground loop interference on the 4-20 mA loop protocol.
  • Maintain minimum structural side-clearance around the probe tip during mounting to prevent metallic sidewalls from distorting the eddy-current field.
  • Avoid tight bends or excessive mechanical tension along the 17 m cable assembly; route cabling through dedicated protective metallic conduit.
  • Secure all threaded probe connections using locknuts and thread sealant to prevent mechanical position drift under continuous machine vibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more