Skip to content

What are you looking for?


You may also like

Bently Nevada 172323-01 1900/65A General Purpose Equipment MonitorBently Nevada 172323-01 1900/65A General Purpose Equipment MonitorBently Nevada 172323-01 1900/65A General Purpose Equipment Monitor
Bently Nevada 172323-01 1900/65A General Purpose Equipment Monitor
Bently Nevada 172323-01 1900/65A General Purpose Equipment Monitor
Bently Nevada 172323-01 1900/65A General Purpose Equipment Monitor

Bently Nevada 172323-01 1900/65A General Purpose Equipment Monitor


Only 10 left - Selling fast

PRODUCT SKU : 1900/65A 172323-01

PRODUCT TYPE : Equipment Monitors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 172323-01 is a 1900/65A General Purpose Equipment Monitor designed to provide continuous vibration and temperature monitoring for critical industrial machinery. It processes sensor inputs to perform automated machinery protection and real-time condition monitoring.

Channel Configuration and Signal Outputs

The monitor features four transducer inputs that accept accelerometers, velocity sensors, or proximity probes, alongside four dedicated temperature inputs compatible with thermocouples and RTDs. For control and logging, the unit provides six programmable relay outputs for alarms, four 4-20 mA analog outputs for recorders or control systems, and one dedicated buffered output for direct dynamic signal access.

Networking and Mechanical Profile

Built-in Modbus communication allows data integration over Ethernet or RS232/RS485 serial interfaces. The compact hardware assembly measures 19.6 cm x 16 cm x 8 cm and has an overall weight of 0.98 kg.

Parameter Specification
Model 172323-01 (1900/65A)
Brand Bently Nevada
Product Category General Purpose Equipment Monitors
Transducer Inputs 4 channels (accelerometers, velocity sensors, or proximity probes)
Temperature Inputs 4 channels (thermocouples and RTDs)
Relay Outputs 6 channels (alarms and control)
Analog Outputs 4 channels (4-20 mA)
Buffered Output 1 dedicated output
Communication Protocols Modbus (Ethernet, RS232 / RS485)
Dimensions 19.6 cm x 16 cm x 8 cm
Weight 0.98 kg

Frequently Asked Questions

Q: What sensor types are supported on the transducer input channels?

A: The four transducer input channels support accelerometers, velocity sensors, and proximity probes.

Q: What signal outputs are available on the Bently Nevada 172323-01 for external control systems?

A: The monitor provides six alarm relay outputs, four 4-20 mA analog outputs, and one dedicated buffered signal output.

Q: How does the monitor interface with supervisory networks?

A: It supports Modbus communication over Ethernet as well as RS232/RS485 serial connections.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more