Only 10 left - Selling fast

PRODUCT SKU : 140CPS11100

PRODUCT TYPE : Power Supply Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric 140CPS11100 serves as a high-performance standalone power supply module for the Modicon Quantum automation platform. It converts AC input voltage into a stabilized 5.1V DC output to energize modules residing on the Quantum backplane. This unit provides a steady 3A current, supporting medium-to-large I/O configurations with high conversion efficiency. We offer this module as 100% brand new, original equipment in factory-sealed packaging, ensuring maximum system uptime for your critical control infrastructure.

Technical Specifications

The 140CPS11100 accommodates a wide range of AC input voltages and provides comprehensive internal protection for the backplane electronics.

Feature Specification
Input Voltage 120...230 V AC (Range: 100...276 V)
Input Frequency 47 to 63 Hz
Output Voltage 5.1 V DC
Output Current 3 A (Standalone)
Rated Power 50 VA
Inrush Current 10 A @ 230 V / 20 A @ 115 V
Associated Fuse 1.5 A, slow-blow
Module Format Standard Quantum Module
Net Weight 1.43 lb (0.65 kg)
Operating Temp 32 to 140 °F (0 to 60 °C)

Engineering Advantages

  • Wide Range Voltage Compatibility: This module accepts a broad input spectrum from 100V to 276V AC. This flexibility allows the Quantum system to operate reliably across global power grids and handles significant line voltage fluctuations without interrupting the PLC logic.

  • Integrated Overload Protection: Built-in internal overvoltage and overload protection circuits shield the expensive processor and I/O modules from power surges or field-side faults. This eliminates the risk of cascading hardware failure during electrical anomalies.

  • Low Harmonic Distortion: The 140CPS11100 limits harmonic distortion to less than 10% of the fundamental RMS value. This clean power output prevents electromagnetic interference with sensitive analog I/O modules, ensuring high signal integrity throughout the rack.

  • Rapid Diagnostic Feedback: A prominent green "PWR OK" LED provides immediate visual confirmation of the power status. Engineers can verify the health of the DC bus at a glance, significantly speeding up onsite troubleshooting during commissioning or maintenance.

  • Hazardous Location Certification: With FM Class 1 Division 2 certification and UL 508 compliance, this power supply operates safely in volatile industrial environments, such as oil and gas or chemical processing facilities.

FAQs

  • Can I use the 140CPS11100 in a redundant power configuration?

    No. This specific model functions as a standalone power supply. If your application requires redundant power (summing two supplies), you should select a Quantum module specifically designed for redundancy, such as the 140CPS114x0 series.

  • What type of fuse should I use for external protection?

    Schneider recommends an associated 1.5 A slow-blow fuse. This protects the module from high inrush currents during startup while maintaining a safety buffer for continuous operation.

  • Does the 140CPS11100 support high-altitude installations?

    Yes. This module maintains its rated performance at operating altitudes up to 16,404.2 feet (5000 m), making it suitable for specialized mining or aerospace testing facilities.

  • Is this a refurbished or surplus unit?

    Absolutely not. We guarantee this 140CPS11100 is 100% Brand New original Schneider Electric stock. It arrives in the original factory package with the GTIN 3595861135208 intact.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more