Skip to content

What are you looking for?


You may also like

FC-SAI-1620M | Honeywell Safety Manager Analog Input ModuleFC-SAI-1620M | Honeywell Safety Manager Analog Input ModuleFC-SAI-1620M | Honeywell Safety Manager Analog Input Module
FC-SAI-1620M | Honeywell Safety Manager Analog Input Module
FC-SAI-1620M | Honeywell Safety Manager Analog Input Module
FC-SAI-1620M | Honeywell Safety Manager Analog Input Module

FC-SAI-1620M | Honeywell Safety Manager Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : FC-SAI-1620M

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The FC-SAI-1620M from Honeywell is a compact analog input module engineered for integration into Safety Manager systems. With 16 channels and 24 VDC operation, it provides precise signal acquisition for safety-critical applications. Its slim design allows efficient installation in control cabinets while maintaining high reliability in demanding environments.

Technical Specifications

  • Model Number: FC-SAI-1620M

  • Manufacturer: Honeywell

  • Type: Safety Manager System Module

  • Input Channels: 16 analog inputs

  • Operating Voltage: 24 VDC

  • Dimensions (H × W × D): 2 cm × 19 cm × 12.8 cm (0.8 in × 7.5 in × 5 in)

  • Weight: 0.14 kg

  • Condition: New, original packaging

  • Origin: USA

  • Warranty: 12 months

Key Features

  • High-Density Input: 16 analog channels in a single compact module

  • Safety Integration: Designed for Honeywell Safety Manager platforms in critical process environments

  • Compact Design: Slim profile for space-efficient cabinet installation

  • Reliable Performance: Accurate analog signal acquisition for safety monitoring

  • Ease of Deployment: Short lead times and global availability

Application Scenarios

The FC-SAI-1620M is suitable for:

  • Safety Instrumented Systems (SIS) in petrochemical plants

  • Process monitoring in power generation facilities

  • Hazardous area installations requiring reliable analog input acquisition

  • Distributed control systems with high-density input requirements

FAQ

Q: How many channels does the module support?  A: It supports 16 analog input channels.

Q: What voltage does the module operate on?  A: The module operates on 24 VDC.

Q: Is it suitable for compact installations?  A: Yes, its slim design allows easy integration into control cabinets.

Comparison with Similar Models

  • FC-TSAI-1620M: Termination assembly for analog input signals, designed for hazardous environments.

  • FC-SAI-1620M: Analog input module optimized for Safety Manager systems with compact design.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more