Skip to content

What are you looking for?


You may also like

ProSoft | MVI56-MCMR | Modbus Communication Module (Reduced Data Block)ProSoft | MVI56-MCMR | Modbus Communication Module (Reduced Data Block)ProSoft | MVI56-MCMR | Modbus Communication Module (Reduced Data Block)
ProSoft | MVI56-MCMR | Modbus Communication Module (Reduced Data Block)
ProSoft | MVI56-MCMR | Modbus Communication Module (Reduced Data Block)
ProSoft | MVI56-MCMR | Modbus Communication Module (Reduced Data Block)

ProSoft | MVI56-MCMR | Modbus Communication Module (Reduced Data Block)


Only 10 left - Selling fast

PRODUCT SKU : MVI56-MCMR

PRODUCT TYPE : Modbus Communication Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MVI56-MCMR module from ProSoft Technology is a Modbus communication interface designed for Allen Bradley ControlLogix systems. This version features a reduced data block, making it suitable for applications that require smaller memory mapping while maintaining full Modbus RTU and ASCII communication capabilities.

Key Specifications

  • Manufacturer: ProSoft Technology / Allen Bradley

  • Model: MVI56-MCMR

  • Part Number: MVI56-MCMR

  • Product Type: Modbus Communication Module (Reduced Data Block)

  • Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC

  • Operating Temperature: 0–60°C (32–140°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Shock Resistance: 30 g operational, 50 g non-operational

  • Vibration Resistance: 5 g, 10–150 Hz

  • Relative Humidity: 5–95% non-condensing

  • Configuration Port (CFG): RJ45 (DB-9M adapter supplied), RS-232 only

  • Communication Parameters:

    • Baud Rate: 110–115,200 baud

    • Stop Bits: 1 or 2

    • Data Size: 7 or 8 bits

    • Parity: None, Even, Odd

    • RTS Timing Delay: 0–65,535 ms

  • Modbus Modes: RTU (binary with CRC-16) and ASCII (with LRC error checking)

  • Floating Point Support: Enron, Daniel®, and other implementations supported

  • Shipping Weight: 2 kg

Core Features

  • Reduced data block design for optimized memory usage

  • Full support for Modbus RTU and ASCII communication modes

  • Configurable communication parameters for flexible integration

  • Floating point data handling with industry-standard implementations

  • Diagnostic LED indicators for monitoring module status

Application Scenarios

  • Integration of Modbus devices into ControlLogix systems with limited memory requirements

  • SCADA and distributed control systems requiring Modbus RTU or ASCII communication

  • Industrial automation setups needing configurable communication parameters

FAQ

  • Q: What distinguishes the MVI56-MCMR from the MVI56-MCM?  A: The MCMR version uses a reduced data block, making it suitable for applications with smaller memory requirements.

  • Q: Which Modbus modes are supported?  A: Both RTU (binary with CRC-16) and ASCII (with LRC error checking).

  • Q: Does the module support floating point data?  A: Yes, including Enron and Daniel-style implementations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more