Skip to content

What are you looking for?


You may also like

ProSoft PLX32-EIP-SIE Ethernet/IP to Siemens Industrial Ethernet Gateway ModuleProSoft PLX32-EIP-SIE Ethernet/IP to Siemens Industrial Ethernet Gateway ModuleProSoft PLX32-EIP-SIE Ethernet/IP to Siemens Industrial Ethernet Gateway Module
ProSoft PLX32-EIP-SIE Ethernet/IP to Siemens Industrial Ethernet Gateway Module
ProSoft PLX32-EIP-SIE Ethernet/IP to Siemens Industrial Ethernet Gateway Module
ProSoft PLX32-EIP-SIE Ethernet/IP to Siemens Industrial Ethernet Gateway Module

ProSoft PLX32-EIP-SIE Ethernet/IP to Siemens Industrial Ethernet Gateway Module


Only 10 left - Selling fast

PRODUCT SKU : PLX32-EIP-SIE

PRODUCT TYPE : EtherNet/IP Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The PLX32-EIP-SIE by ProSoft Technology is a high-performance communication gateway designed for seamless, bidirectional data exchange between Rockwell Automation PACs using EtherNet/IP™ and Siemens S7 PLCs via Industrial Ethernet. Engineered for multi-vendor and complex network environments, it supports independent subnets, advanced diagnostics, and multiple PLC types on both interfaces.

Protocol Support

EtherNet/IP™ Side

  • Supported PLCs: PLC-2, PLC-5, SLC, ControlLogix, CompactLogix, MicroLogix

  • Message Types: PCCC and CIP

  • Class 3 Connections: 5 Server, 2 Client (connected), 1 Client (unconnected)

  • Class 1 I/O Connections: 2

  • I/O Data Size: 248 bytes input / 248 bytes output

  • Maximum RPI: 5 ms per connection

  • CIP Services: Data Table Read (0x4C), Data Table Write (0x4D)

  • Command List: Up to 100 commands per client

Siemens Industrial Ethernet Side

  • Supported PLCs: S7-200, S7-300, S7-400, S7-1200, S7-1500

  • Register Types: Data Blocks (DB), Inputs, Outputs, Flags, Counters, Timers

  • Supported Clients: Up to 20 concurrent connections

Hardware Specifications

  • Power Supply: 24 VDC nominal (range: 10–36 VDC)

  • Current Load: Typical 300 mA, Max 610 mA @ 24 VDC

  • Dimensions: 13.67 × 5.05 × 11.13 cm

  • Weight: 0.5 kg

Applications

Suitable for: Industrial networks requiring integration of Rockwell Automation PACs with Siemens PLCs, multi-vendor environments, and complex automation systems needing reliable, low-latency communication.

FAQ

Q: How many EtherNet/IP client connections are supported?
A: Up to 2 connected and 1 unconnected Class 3 client connections.

Q: Which Siemens PLC models are compatible with this gateway?
A: S7-200, S7-300, S7-400, S7-1200, and S7-1500.

Q: What is the maximum data size per I/O connection on EtherNet/IP?
A: 248 bytes for both input and output per connection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more