Skip to content

What are you looking for?


You may also like

PLX31-EFP-MBS | ProSoft | Ethernet/IP to Modbus Serial GatewayPLX31-EFP-MBS | ProSoft | Ethernet/IP to Modbus Serial GatewayPLX31-EFP-MBS | ProSoft | Ethernet/IP to Modbus Serial Gateway
PLX31-EFP-MBS | ProSoft | Ethernet/IP to Modbus Serial Gateway
PLX31-EFP-MBS | ProSoft | Ethernet/IP to Modbus Serial Gateway
PLX31-EFP-MBS | ProSoft | Ethernet/IP to Modbus Serial Gateway

PLX31-EFP-MBS | ProSoft | Ethernet/IP to Modbus Serial Gateway


Only 10 left - Selling fast

PRODUCT SKU : PLX31-EIP-PND

PRODUCT TYPE : Ethernet/IP to Modbus Serial Gateway

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The PLX31-EFP-MBS by ProSoft provides robust bidirectional communication between Rockwell Automation ControlLogix® and CompactLogix® controllers and Modbus serial devices. It enables reliable data exchange across complex industrial networks while supporting both EtherNet/IP and Modbus serial protocols.

Key Features

  • Dual-protocol gateway: EtherNet/IP to Modbus Serial

  • Client/server support: Multiple connections for ControlLogix and CompactLogix systems

  • Serial interfaces: RS232, RS422, RS485

  • High-speed communication: Low-latency industrial data exchange

  • Floating-point support: Enron and Daniel formats with configurable parity, data, and stop bits

Technical Specifications

EtherNet/IP Interface

  • Class 3 Server Connections: 5

  • Class 3 Client Connections: 2 connected, 1 unconnected

  • Class 1 I/O Connections: 2

  • Maximum I/O Size: 248 bytes input/output

  • Maximum RPI Time: 5 ms per connection

  • CIP Services: Data Table Read (0x4C), Data Table Write (0x4D)

Modbus Serial Interface

  • Supported Function Codes: 1, 2, 3, 4, 5, 6, 15, 16, 22, 23

  • Baud Rate Range: 110 to 115.2 kbps

  • Data Bits: 7 or 8

  • Stop Bits: 1 or 2

  • Parity: None, Even, Odd

  • Communication Modes: RTU (CRC-16), ASCII (LRC)

  • Floating-Point Formats: Enron, Daniel

  • Slave Address Range: 1–247

  • Serial Ports: RS232, RS422, RS485

General

  • Model: PLX31-EFP-MBS

  • Brand: ProSoft

  • Product Type: Ethernet/IP to Modbus Serial Gateway

Applications

Suitable for: Integrating Rockwell Automation PLCs with Modbus serial devices in factory automation, process control, and networked industrial systems requiring reliable bidirectional communication.

FAQ

Q: How many EtherNet/IP client connections does the gateway support?
A: Up to 2 connected and 1 unconnected Class 3 client connections.

Q: Which Modbus serial interfaces are supported?
A: RS232, RS422, and RS485.

Q: Can the gateway handle floating-point data?
A: Yes, it supports Enron and Daniel floating-point formats.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more