MV156E-MNET | ProSoft | ControlLogix Modbus TCP/IP Enhanced Client/Server ModuleMV156E-MNET | ProSoft | ControlLogix Modbus TCP/IP Enhanced Client/Server ModuleMV156E-MNET | ProSoft | ControlLogix Modbus TCP/IP Enhanced Client/Server Module
MV156E-MNET | ProSoft | ControlLogix Modbus TCP/IP Enhanced Client/Server Module
MV156E-MNET | ProSoft | ControlLogix Modbus TCP/IP Enhanced Client/Server Module
MV156E-MNET | ProSoft | ControlLogix Modbus TCP/IP Enhanced Client/Server Module

MV156E-MNET | ProSoft | ControlLogix Modbus TCP/IP Enhanced Client/Server Module


Only 10 left - Selling fast

PRODUCT SKU : MV156E-MNET

PRODUCT TYPE : Server Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MVI56E-MNET module from ProSoft Technology is an enhanced Modbus TCP/IP client/server communication interface designed for Allen Bradley ControlLogix systems. It provides high-speed Ethernet connectivity, expanded data handling, and diagnostic features for reliable integration of Modbus devices into ControlLogix platforms.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Model: MVI56E-MNET

  • Part Number: MVI56E-MNET

  • Product Type: Modbus TCP/IP Enhanced Client/Server Module

  • Product Line: ControlLogix

  • Weight: 3.00 lbs (1.36 kg)

  • Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC

  • Module Width: Single slot

  • Compatible Rack: ControlLogix chassis (local or remote)

  • Data Size: 5000 words, 16-bit registers

  • User-Definable Memory Mapping: Up to 5000 registers

  • Configuration Tools: Add-On-Instruction (AOI), sample ladder logic

  • Compatible Processors: ControlLogix processor version 10 or higher

  • Communication Port: 1 × RJ45 Ethernet interface

  • Ethernet Speed: 10/100 Mbps (Base-T)

  • LED Indicators: Battery status (ERR), application status (APP), module status (OK)

  • Operating Temperature: 0–60°C (32–140°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Shock Resistance: 30 g operational

  • Relative Humidity: 5–95% non-condensing

  • Protection: Conformal-coated for harsh environments

Core Features

  • Enhanced Modbus TCP/IP client/server communication for ControlLogix systems

  • Large data handling capacity with flexible memory mapping

  • AOI and ladder logic integration for simplified configuration

  • Diagnostic LEDs for real-time monitoring of module and communication status

  • Rugged design with conformal coating for industrial reliability

Application Scenarios

  • Integration of Modbus TCP/IP devices into ControlLogix systems

  • SCADA and distributed control systems requiring Modbus communication

  • Industrial automation setups needing floating-point data handling and Ethernet connectivity

FAQ

  • Q: How many registers can be mapped?  A: Up to 5000 registers.

  • Q: What configuration tools are supported?  A: Add-On-Instruction (AOI) and sample ladder logic.

  • Q: What processors are compatible?  A: ControlLogix processors version 10 or higher.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more