PRODUCT SKU : LD SYN-101 3BHE005555R0101

PRODUCT TYPE : Synchronization Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB LD SYN-101 3BHE005555R0101, also cataloged as the LDSYN-101 Synchronization Board, operates as a dedicated hardware component for high-precision pulse synchronization and signal conversion within ABB industrial control systems.

Hardware Specifications

Parameter Specification
Model LD SYN-101 (3BHE005555R0101)
Brand ABB
Origin Switzerland
Weight 0.35 kg
Dimensions 23 cm x 11 cm x 3.4 cm
Operating Temp -10 to +55 deg C
Power Consumption 24 VDC +/-20%, maximum 0.5 A input current
Storage Temp -20 to +70 deg C
Humidity Limits 10% to 90% (non-condensing)
Signal Processing Pulse conversion and high-precision signal synchronization
Product Type Synchronization Board / Power Module

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The LD SYN-101 3BHE005555R0101 module converts high-frequency synchronization pulse trains without compromising backplane bus communication velocity across system chassis backplanes. Integrated protocol interfaces convert field signals while maintaining deterministic scan rates. Full firmware flash compatibility with host control units ensures uniform clock alignment, low phase variance, and scalable I/O density scaling across distributed control racks.

Frequently Asked Questions

Q: What power input range is permitted for operating the LD SYN-101 module?

A: The module requires a nominal 24 VDC power supply with an allowable tolerance of +/-20% and a peak input current of 0.5 A.

Q: How does the module maintain system timing during multi-node operation?

A: The board executes hardware-level signal conversion to synchronize incoming pulses across communication interfaces with negligible phase jitter.

Q: Is hot-swapping permitted for the LD SYN-101 module during active operation?

A: Auxiliary 24 VDC power and field communication links must be isolated prior to removing or inserting the board to prevent transient voltage spikes on the backplane bus.

Field Installation Guidelines

  1. Disconnect main 24 VDC power supplies and communication cables before handling the LD SYN-101 module.
  2. Wear an ESD wrist strap connected to a verified ground point to prevent static discharge to logic circuits.
  3. Align the board edges with the subrack guide rails and insert the module until the backplane connectors seat completely.
  4. Fasten the faceplate retention screws to secure structural earth grounding and mechanical positioning.
  5. Apply power and verify LED status indicators to confirm stable communication and firmware flash compatibility.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more