Skip to content

What are you looking for?


You may also like

Yokogawa AAI141-S50 16-Channel Non-Isolated Analog Input ModuleYokogawa AAI141-S50 16-Channel Non-Isolated Analog Input ModuleYokogawa AAI141-S50 16-Channel Non-Isolated Analog Input Module
Yokogawa AAI141-S50 16-Channel Non-Isolated Analog Input Module
Yokogawa AAI141-S50 16-Channel Non-Isolated Analog Input Module
Yokogawa AAI141-S50 16-Channel Non-Isolated Analog Input Module

Yokogawa AAI141-S50 16-Channel Non-Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAI141-S50

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI141-S50 analog input module from Yokogawa is part of the Field I/O (FIO) platform, designed for accurate current signal acquisition in industrial automation systems. Unlike isolated modules, the AAI141-S50 is a non-isolated unit, optimized for applications where isolation is not required but precision and reliability remain critical. With 16 input channels, this module supports 4–20 mA DC signals and integrates seamlessly into dual-redundant configurations, ensuring system stability and dependable performance.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI141-S50

  • Type: Non-Isolated Analog Input Module

  • Channels: 16 analog input channels

  • Signal Range: 4–20 mA DC

  • Accuracy: ±0.1% of full scale

  • Resolution: 16-bit

  • Operating Temperature: -20°C to +70°C

  • Power Supply: 24 V DC

  • Redundancy: Dual-redundant configuration supported

  • Current Consumption:

    • 310 mA (5 V DC)

    • 450 mA (24 V DC)

  • Update Period: 10 ms

  • Step Response Time: 100 ms

  • Weight: 0.2 kg

Key Features

  • Non-Isolated Design: Simplifies installation where isolation is not required

  • High Resolution: 16-bit conversion for precise signal measurement

  • Compact and Lightweight: At 0.2 kg, easy to install and maintain

  • Dual-Redundancy Support: Ensures reliability in critical control systems

  • Energy Efficient: Low current consumption for stable operation

Application Scenarios

  • Oil and gas process monitoring

  • Chemical and pharmaceutical manufacturing

  • Power generation instrumentation

  • General industrial automation requiring non-isolated current input

FAQ

Q: How many channels does the AAI141-S50 provide?  A: It supports 16 non-isolated analog input channels.

Q: What type of signals can this module measure?  A: It is designed for 4–20 mA DC current signals.

Q: Is redundancy supported?  A: Yes, the module supports dual-redundant configurations for increased reliability.

Comparison with Similar Models

  • AAI143-S50: Isolated analog input module with HART support

  • AAI141-S50: Non-isolated version, optimized for simpler installations

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more