Woodward 9907-167 Digital GovernorWoodward 9907-167 Digital GovernorWoodward 9907-167 Digital Governor
Woodward 9907-167 Digital Governor
Woodward 9907-167 Digital Governor
Woodward 9907-167 Digital Governor

Woodward 9907-167 Digital Governor


Only 10 left - Selling fast

PRODUCT SKU : 9907-167

PRODUCT TYPE : Digital Governors

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Woodward 9907-167, also cataloged as the 9907-167 Digital Governor, operates as a dedicated hardware component for 32-bit microprocessor-based steam turbine control within industrial governing systems.

Hardware Specifications

Parameter Specification
Model 9907-167
Brand Woodward
Origin USA
Weight < 10 lbs
Dimensions 14 x 11 x 4 inches
Operating Temp -25 to 65 deg C (Standard); -25 to 55 deg C (w/ NEMA 4X)
Power Consumption 18 - 32 VDC
Processor 32-bit microprocessor
Actuator Outputs 2
Relay Outputs 8
Programmable Current Outputs 6
Shock Protection US MIL-STD-810C, method 516.2- 1, procedure 1B

Actuator Loop Feedback Response

The 9907-167 maintains precise turbine valve positioning via two dedicated actuator outputs. These outputs provide the necessary control signals to modulate inlet steam valves, utilizing high-speed feedback loops to ensure stable governor response. The system resolution is managed via a 32-bit architecture, which minimizes latency in actuator command execution. Periodic calibration of the actuator loop feedback is required to maintain steam turbine stability, particularly when operating under variable extraction or admission pressure conditions.

Frequently Asked Questions

Q: Can the 9907-167 support field configuration changes?

A: Yes, the unit is equipped with program upload and download capability via the operator interface, allowing for site-specific parameter adjustments to the governor control logic.

Q: How does the NEMA 4X enclosure affect thermal performance?

A: The addition of a NEMA 4X protective casing limits the maximum allowable ambient operating temperature from 65 deg C down to 55 deg C. Ensure adequate ventilation or auxiliary cooling is provided if the cabinet temperature approaches this limit.

Field Installation Guidelines

  1. Mounting: Ensure the enclosure is securely fastened within a control panel. If utilizing the NEMA 4X casing, confirm all seals are intact to maintain the ingress protection rating.
  2. Grounding: Verify the control chassis is connected to a common earth ground to mitigate electromagnetic interference and ensure stable 32-bit processor operation.
  3. Wiring: Route signal lines (analog/actuator) separately from high-voltage AC power cables to prevent induced noise in the current output loops.
  4. Interface: Utilize the 30-key keypad and 2-row display for initial commissioning and verification of I/O status prior to putting the turbine online.
  5. Validation: Before startup, perform a cold-loop check of the 8 relay outputs and 6 current outputs to verify continuity and signal integrity to the field devices.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more