The Woodward 5466-318, also cataloged as the 5466-318 Kernel Power Supply Module, operates as a dedicated hardware component for Triple Modular Redundant (TMR) power regulation within MicroNet TMR control platforms.

Hardware Specifications

Parameter Specification
Model 5466-318
Brand Woodward
Power Consumption 24 VDC
Input Voltage 24 VDC +/- 10%
Output Voltage 5 VDC +/- 5%
Output Current 10 A (max)
CPU Compatibility TMR040
Chassis MicroNet TMR

Triple Modular Redundancy (TMR) 2oo3 Architecture

The 5466-318 is architected specifically for integration into a MicroNet TMR system, functioning as one of three redundant kernel power supply modules. In a TMR 2oo3 architecture, the module ensures continuous operation through fault-tolerant power distribution. The unit performs galvanic isolation between the primary 24 VDC MicroNet bus and the regulated internal 5 VDC rails, ensuring that a failure in a single power module does not propagate to the other two modules within the TMR cluster. Fail-safe state execution is maintained by the synchronization of the three modules, allowing for uninterrupted system power in the event of an individual module fault or input supply disturbance.

Frequently Asked Questions

Q: What is the procedure for removing the 5466-318 module from the MicroNet TMR chassis?

A: Before extraction, all associated kernel power supply modules within the TMR cluster must be removed to prevent electrical contention or backplane damage. Ensure the system is powered down and the modules are extracted in accordance with the specified hardware removal sequence.

Q: How is the power health status indicated on the front faceplate?

A: The front faceplate features a single status LED. When illuminated, this indicator provides visual confirmation of the internal Power Health supply status. If the LED is extinguished, the module is failing to provide the regulated 5 VDC output, signaling a potential internal fault.

Field Installation Guidelines

  1. Mounting: Insert the module into the first slot of the MicroNet TMR kernel section. Ensure the module is seated fully into the backplane connectors to establish electrical continuity.
  2. Environmental Constraints: Installation is limited to non-hazardous locations or Class I, Groups A, B, C, D, Division 2 locations. Verify the installation site environment meets these criteria to prevent operational errors.
  3. Power Cabling: Ensure the 24 VDC main power source is stable and within the +/- 10% tolerance range. Use appropriately rated wiring to support the 10 A current throughput.
  4. Validation: Monitor the front panel LED upon power-up. In a redundant configuration, all three modules must exhibit active status indicators to confirm healthy synchronization of the TMR power bus.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more