Skip to content

What are you looking for?


You may also like

VersaMax IC200MDL650 | GE Fanuc 24VDC 32-Point Input ModuleVersaMax IC200MDL650 | GE Fanuc 24VDC 32-Point Input ModuleVersaMax IC200MDL650 | GE Fanuc 24VDC 32-Point Input Module
VersaMax IC200MDL650 | GE Fanuc 24VDC 32-Point Input Module
VersaMax IC200MDL650 | GE Fanuc 24VDC 32-Point Input Module
VersaMax IC200MDL650 | GE Fanuc 24VDC 32-Point Input Module

VersaMax IC200MDL650 | GE Fanuc 24VDC 32-Point Input Module


Only 10 left - Selling fast

PRODUCT SKU : IC200MDL650

PRODUCT TYPE : Discrete Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC200MDL650 is a high-performance 32-point discrete input module from GE Fanuc, engineered for seamless integration with VersaMax PLC systems. This module features four isolated input groups with eight channels each, providing reliable signal acquisition and robust electrical isolation in demanding industrial environments. Compact and efficient, it is ideal for control panels requiring multiple DC inputs.

Key Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC200MDL650

  • Series: VersaMax I/O

  • Module Type: 24VDC Discrete Input Module

  • Number of Input Points: 32 (4 groups of 8 channels)

  • Nominal Input Voltage: 24 VDC

  • Input Voltage Range: 0–30 VDC

  • Output Voltage Range: 18–30 VDC

  • On-State Voltage: 15–30 VDC

  • Off-State Voltage: 0–5 VDC

  • On-State Current: 2.0–5.5 mA per point

  • Off-State Current: 0–0.5 mA per point

  • Input Impedance: 10 kΩ

  • Input Response Time: 0.5 ms maximum

  • Filter Time Options: 0 ms / 1 ms / 7 ms

  • Group-to-Group Isolation: 250 VAC continuous, 1500 VAC for 1 minute

  • Point-to-Point Isolation: None

  • Backplane Current Consumption (5V): 50 mA maximum

  • LED Indicators: Individual LED per input point, OK LED for backplane status

  • External Power Supply: Not required

  • Weight: 0.69 lbs (0.31 kg)

Features

  • High-density 32-point input configuration with four isolated groups

  • Fast 0.5 ms maximum response time

  • Flexible filter settings for signal conditioning

  • Robust isolation for safe operation in industrial environments

  • LED indicators for each channel simplify diagnostics

  • Compact size allows easy integration into standard VersaMax I/O carriers

Applications

  • Monitoring discrete DC signals from sensors, switches, and control devices

  • Expanding input capacity in VersaMax PLC systems

  • Industrial process automation requiring high-density discrete inputs

FAQ / Comparison

  • Q: How does IC200MDL650 differ from IC200MDL640?
    A: IC200MDL650 offers 32 DC input points in 4 groups, while IC200MDL640 provides 16 DC input points in 2 groups.

  • Q: Is an external power supply needed?
    A: No, the module draws power directly from the VersaMax backplane.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more