Skip to content

What are you looking for?


You may also like

TC-IAH161 | Honeywell High-Level Analog Input Module 16-ChannelTC-IAH161 | Honeywell High-Level Analog Input Module 16-ChannelTC-IAH161 | Honeywell High-Level Analog Input Module 16-Channel
TC-IAH161 | Honeywell High-Level Analog Input Module 16-Channel
TC-IAH161 | Honeywell High-Level Analog Input Module 16-Channel
TC-IAH161 | Honeywell High-Level Analog Input Module 16-Channel

TC-IAH161 | Honeywell High-Level Analog Input Module 16-Channel


Only 10 left - Selling fast

PRODUCT SKU : TK-IAH161

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TC-IAH161 from Honeywell is a high-level analog input module designed for precise voltage and current measurement across 16 channels. Built for industrial automation, it delivers reliable performance and robust signal integrity for critical control applications.

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: TC-IAH161

  • Product Type: High-Level Analog Input Module

  • Channels: 16

  • Voltage Input Ranges: ±10.25 V, 0–10.25 V, 0–5.125 V

  • Current Input Range: 0–20.5 mA (via internal 250 Ω resistor)

  • Resolution: 16-bit across all ranges

  • Module Publish Rate: 250 ms

  • Input Impedance: Voltage >1 MΩ, Current 249 Ω nominal

  • Channel Bandwidth: 20 Hz (-3 dB)

  • RFI Immunity: <2% of range at 10 V/m, 27–1000 MHz

  • Power Dissipation: 4.1 W max

  • Isolation Voltage (User to System): 2550 VDC, 1 s

  • Terminal Connection: TC-TBCH, 36-position block

  • Shipping Weight: 1.5 kg

  • Operating Temperature: Standard industrial range

  • Construction: Rugged, low-power design for long-term reliability

Features

  • High Accuracy: 16-bit resolution ensures precise analog measurement

  • Multi-Range Input: Supports both voltage and current signals

  • RFI Resistant: Maintains <2% error across wide frequency spectrum

  • Robust Isolation: Protects system and user circuits with 2550 VDC tested isolation

  • Compact Layout: 16-channel design optimized for TC-TBCH terminal blocks

  • Durable Build: Low power dissipation and industrial-grade materials for consistent performance

Applications

  • Process control requiring multiple analog inputs

  • Monitoring of voltage and current sensors

  • Integration with Experion PKS and TDC 3000 systems

FAQ

Q: What is the primary function of the TC-IAH161 module?
A: It converts analog voltage and current signals into digital values for control and monitoring systems.

Q: How many channels are supported?
A: 16 channels, each with high-precision 16-bit resolution.

Q: How does it handle electrical interference?
A: RFI immunity ensures less than 2% measurement error at 10 V/m over 27–1000 MHz.

Q: Which industries benefit from this module?
A: Suitable for manufacturing, power generation, chemical processing, and water treatment facilities.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more