Skip to content

What are you looking for?


You may also like

SAI143-H33 | Yokogawa | 16-Channel Isolated Analog Input Module with Transmitter PowerSAI143-H33 | Yokogawa | 16-Channel Isolated Analog Input Module with Transmitter PowerSAI143-H33 | Yokogawa | 16-Channel Isolated Analog Input Module with Transmitter Power
SAI143-H33 | Yokogawa | 16-Channel Isolated Analog Input Module with Transmitter Power
SAI143-H33 | Yokogawa | 16-Channel Isolated Analog Input Module with Transmitter Power
SAI143-H33 | Yokogawa | 16-Channel Isolated Analog Input Module with Transmitter Power

SAI143-H33 | Yokogawa | 16-Channel Isolated Analog Input Module with Transmitter Power


Only 10 left - Selling fast

PRODUCT SKU : SAI143-H33

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The SAI143-H33 from Yokogawa is a high‑precision analog input module designed for advanced process control applications. It provides 16 isolated input channels with flexible transmitter power supply management, making it suitable for integration into distributed control systems where accuracy and reliability are critical.

This module supports 4–20 mA DC current loop signals with a permissible input range up to 25 mA. Each channel is galvanically isolated, ensuring protection against ground loops and electrical noise. The SAI143-H33 also offers configurable transmitter power supply settings, enabling simultaneous ON/OFF control across all channels in two‑wire mode.

Technical Specifications

  • Model / Order Number: SAI143-H33

  • Manufacturer: Yokogawa Electric Corporation

  • Type: Analog Input Module

  • Channels: 16 isolated inputs

  • Rated Input Range: 4–20 mA

  • Permissible Input Range: 0–25 mA

  • Input Impedance (Power ON): 250 Ω + current value (≈272.5 Ω at 20 mA, ≈362.5 Ω at 4 mA)

  • Input Impedance (Power OFF): ≥500 kΩ

  • Accuracy: ±16 µA (0.05–23 mA input range)

  • Data Update Frequency: 40 ms

  • Temperature Drift: ±16 µA per 10°C

  • Transmitter Power Supply:

    • Minimum 16.15 V at 20 mA

    • Maximum 26.4 V at 0 mA

    • Output current limit: 25 mA

    • Individual channel setting available

    • ON/OFF control for all 16 channels in 2‑wire mode

  • Isolation Voltage: 1.5 kV AC (input to system, 1 minute)

  • Current Consumption: 320 mA (5 V system), 550 mA (24 V system)

  • Weight: Approx. 0.34 kg (pressure clamp terminal or MIL cable), 0.39 kg (with signal cable adapter)

  • External Connections: Pressure clamp terminal, MIL cable, dedicated signal cable

  • Operating Temperature: -20°C to +70°C

Application Scenarios

  • High‑accuracy transmitter integration in process industries

  • Distributed control systems requiring isolated analog inputs

  • Environments with wide operating temperature ranges

FAQ

Q: How many channels does the SAI143-H33 support?  A: It supports 16 isolated analog input channels.

Q: Does the module provide transmitter power supply control?  A: Yes, it allows individual channel settings and simultaneous ON/OFF control in 2‑wire mode.

Q: What is the accuracy of the SAI143-H33?  A: ±16 µA within the 0.05–23 mA input range.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more