Skip to content

What are you looking for?


You may also like

Safe Digital Output Module FSC | Honeywell FS‑TDO‑1624Safe Digital Output Module FSC | Honeywell FS‑TDO‑1624Safe Digital Output Module FSC | Honeywell FS‑TDO‑1624
Safe Digital Output Module FSC | Honeywell FS‑TDO‑1624
Safe Digital Output Module FSC | Honeywell FS‑TDO‑1624
Safe Digital Output Module FSC | Honeywell FS‑TDO‑1624

Safe Digital Output Module FSC | Honeywell FS‑TDO‑1624


Only 10 left - Selling fast

PRODUCT SKU : FS-TDO-1624

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell FSC FS‑TDO‑1624 Safe Digital Output Module is designed to provide secure and dependable digital signal control in safety‑critical automation systems. Built for integration into Honeywell’s Fault‑Tolerant Safety Controller (FSC) architecture, this module ensures consistent performance across demanding industrial environments.

Technical Specifications

  • Model: FS‑TDO‑1624

  • Manufacturer: Honeywell

  • Type: Safe Digital Output Module

  • Number of Channels: 16 isolated outputs

  • Voltage Range: 24 VDC nominal (18–32 VDC operating range)

  • Output Type: Configurable sourcing or sinking

  • Current Rating: Up to 2 A per channel

  • Communication Protocols: Ethernet/IP, Modbus TCP/IP

  • Operating Temperature: –40 °C to +70 °C (–40 °F to +158 °F)

  • Power Supply: 24 VDC nominal input

  • Warranty: 12 months standard coverage

Key Features

  • Safety‑Certified Design: Engineered for functional safety applications

  • Flexible Output Configuration: Supports both sourcing and sinking modes

  • High Current Capacity: 2 A per channel for robust actuation

  • Wide Temperature Range: Reliable operation in extreme industrial conditions

  • Network Integration: Compatible with Ethernet/IP and Modbus TCP/IP systems

  • System Compatibility: Seamlessly integrates with Honeywell FSC controllers

Application Scenarios

  • Emergency shutdown systems (ESD)

  • Process interlocks in chemical and petrochemical plants

  • Safety logic execution in oil & gas facilities

  • Power generation and heavy manufacturing environments

FAQ

Q: Can the FS‑TDO‑1624 be used in redundant safety architectures?  A: Yes, it can be deployed in redundant configurations to enhance system reliability.

Q: How does this module differ from smaller output modules?  A: The FS‑TDO‑1624 offers 16 channels with higher current capacity, making it suitable for large‑scale safety applications compared to 8‑channel variants.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more