Overview
The Allen-Bradley 1771-IR is a high-precision RTD Input Module designed for accurate temperature measurement and resistance monitoring within 1771 I/O chassis systems. It supports multiple sensor types and provides reliable performance across a wide temperature range, making it ideal for industrial temperature control applications.

Key Features

  • Model Number: 1771-IR

  • Manufacturer: Allen-Bradley

  • Product Type: RTD Input Module

  • Number of Inputs: 6 RTD input channels

  • Module Location: 1771 I/O chassis

  • Sensor Types Supported:

    • 100 Ω platinum (α = 0.00385)

    • 10 Ω copper (α = 0.00386)

    • Other RTDs (resistance readings only)

  • Units of Measurement:

    • Temperature: °C or °F

    • Resistance: Ohms (10 mΩ or 30 mΩ resolution)

Performance Specifications

  • Temperature Range:

    • Platinum RTD: -200°C to +870°C (-328°F to +1598°F)

    • Copper RTD: -200°C to +260°C (-328°F to +500°F)

  • Resistance Range: 1.00 to 600.00 Ω

  • Resolution:

    • Platinum RTD: 0.1°C (0.1°F)

    • Copper RTD: 0.3°C (0.5°F)

  • Sensor Excitation Current: 1 mA constant current per channel

  • Common Mode Impedance: >10 MΩ

  • Input Overvoltage Protection: 120V RMS continuous

  • Power Dissipation: 4.75 W (maximum)

  • Thermal Dissipation: 16.2 BTU/hr

  • Temperature Coefficient: +50 ppm/°C of full-scale range

Applications
The 1771-IR module is commonly used in process control, manufacturing, and industrial automation systems that demand accurate, multi-channel temperature monitoring. Its compatibility with both platinum and copper RTDs makes it versatile for a variety of sensing environments, including furnaces, reactors, and machine temperature feedback loops.

FAQs
Q: What sensors can be used with the 1771-IR module?
A: The module supports 100 Ω platinum and 10 Ω copper RTDs as standard, and can display readings in ohms for other RTD types.

Q: What is the maximum input resistance supported by the 1771-IR?
A: The 1771-IR can measure resistance up to 600 Ω, making it suitable for a wide range of RTD applications.

Q: How accurate is the 1771-IR in temperature measurement?
A: The module provides resolution down to 0.1°C for platinum sensors and 0.3°C for copper sensors, ensuring precise readings for critical processes.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more