Product Details

The GE IS220YDIAS1AK, also cataloged as the IS220YDIA Discrete Contact Input I/O Module, operates as a dedicated hardware component for discrete contact status monitoring within Mark VIe control system networks.

Hardware Specifications

Parameter Specification
Model IS220YDIAS1AK
Brand General Electric
Origin USA
Weight 0.91 kg (2 lbs)
Dimensions 138 x 86 x 56 mm
Operating Temp -30 to 65 deg C
Power Consumption 18 to 32 VDC input supply
System Series Mark VIe
Onboard Memory 256 MB DDR SDRAM
Operating System QNX Neutrino
Software Compatibility ControlST V04.03.18C
Relative Humidity 5% to 95% (non-condensing)

Backplane Bus Communication Velocity and Firmware Flash Compatibility

Powered by the QNX Neutrino real-time operating system and 256 MB of DDR SDRAM, the IS220YDIAS1AK maintains high backplane bus communication velocity across dual IONet Ethernet interfaces. The module digitizes optical and contact sensor inputs, applying noise filtering and sequence-of-events (SOE) timestamping at the hardware layer. Dedicated internal memory architectures ensure full firmware flash compatibility through GE ControlST management software, allowing online flash updates without disturbing adjacent I/O packs on the terminal board.

Frequently Asked Questions

Q: What operating system and memory architecture power the IS220YDIAS1AK module?

A: The module operates on the QNX Neutrino real-time operating system utilizing 256 MB of onboard DDR SDRAM.

Q: What power supply range is required for module operation?

A: The module operates within an input supply range of 18 VDC to 32 VDC.

Q: How is firmware maintained on the IS220YDIAS1AK?

A: The module features firmware flash compatibility managed directly through GE ControlST V04.03.18C or compatible system software.

Field Installation Guidelines

Isolate power to the field terminal board before attaching or removing the IS220YDIAS1AK I/O pack. Maintain electrostatic discharge (ESD) protection by using a grounded wrist strap attached to the metal cabinet frame. Align the module connectors with the matching terminal board interface, push firmly until fully seated, and secure the mechanical retaining screws to establish ground continuity. Connect Ethernet network lines to the designated IONet ports before energizing the 24 VDC power feed.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more