Skip to content

What are you looking for?


You may also like

ICS Triplex T8513 Digital Output ModuleICS Triplex T8513 Digital Output ModuleICS Triplex T8513 Digital Output Module
ICS Triplex T8513 Digital Output Module
ICS Triplex T8513 Digital Output Module
ICS Triplex T8513 Digital Output Module

ICS Triplex T8513 Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : T8513

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : ICS Triplex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ICS Triplex T8513, also cataloged as the T8513 Digital Output Module, operates as a dedicated hardware component for discrete signal command execution within Trusted TMR system platforms. This high-density module facilitates the switching of 32 isolated digital output channels, providing the necessary interface between the safety-critical controller logic and field-side actuators.

Hardware Specifications

Parameter Specification
Model T8513
Brand ICS Triplex
Dimensions Standard Trusted chassis slot
Operating Temp Industrial-grade range
Power Consumption Not Specified
Channel Count 32 digital output channels

SIS Triple Modular Redundancy (TMR) Architecture

The T8513 integrates into a triple modular redundancy (TMR) 2oo3 architecture to facilitate fail-safe state execution. The module utilizes hardware-based voting logic across its three redundant internal channels to identify and isolate discrepancies, ensuring that no single-point hardware failure results in an unintended output state. Each of the 32 channels features galvanic isolation, preventing field-side electrical transients or common-mode noise from propagating back into the module backplane or affecting the integrity of the safety control loop.

Frequently Asked Questions

Q: Does the T8513 support hot-swapping under load?

A: The T8513 is designed for hot-swap operations within a powered Trusted chassis. Ensure that the safety controller is set to a maintenance or inhibited state for the specific output points prior to module extraction to prevent spurious state transitions.

Q: How is the channel status and diagnostic information reported?

A: The module features front-panel LED indicators that provide real-time channel status and fault diagnostic feedback. These indicators display individual channel activity as well as module-level fault conditions, allowing for immediate visual verification of output integrity.

Field Installation Guidelines

  1. Verify that the chassis slot is clear of contaminants and ensure proper orientation before insertion to avoid connector pin damage.
  2. Insert the T8513 into the chassis and apply firm pressure to fully engage the backplane connector before securing the front-panel captive screws.
  3. Terminate field wiring at the designated field termination assembly, ensuring that output shielding is bonded to the common cabinet ground point to minimize electromagnetic interference.
  4. Perform an output continuity and state-transition test via the engineering workstation to verify that each of the 32 digital channels correctly responds to programmed safety logic commands.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more
Optimizing Power Supply Sizing for Industrial Automation Systems

Optimizing Power Supply Sizing for Industrial Automation Systems

The power supply is the silent heartbeat of any industrial automation system. While engineers often prioritize processors and communication protocols, a stable power architecture remains the most critical factor for long-term reliability. In my 15 years of experience, I have found that neglecting power supply sizing often leads to ghost errors, intermittent field device failures, and costly production downtime.

Read more